background image

1

This water heater design has been certified by the Canadian 
Standards Association for installation in recreation vehicles.

 This 

water heater is not for use in marine applications.

service calls & quesTions

 Location and phone numbers of qualified Service Centers can 
be found at our website http:/www.askforatwood.com or call 
866.869.8116 to locate a Service Center.

safeTy alerT symbols

  

Safety Symbols alerting you to potential personal safety hazards.  
Obey all safety messages following these symbols.

 m

 

warning 

m

 

caution

 

avoid possible  

avoid possible 

 

injury or death 

injury and/or property damage

EngLiSH - FranÇaiS

 

•Installation  •Operation  •Maintenance 

  

Effective 07.09.13

literature

 

number

 

MPD 90222

l.P. Gas

on DemanD  

WaTer HeaTer

models

oD50, oD50cW

m

 

warning

fIre Or exPlOsIOn

  •   If the information in this manual is not followed 

exactly, a fire or explosion may result causing 
property damage, personal injury or loss of life.

–   Do not store or use gasoline or other flammable vapors  

and liquids in the vicinity of this or any other appliance.

WHaT To Do if you smell Gas 

•   Evacuate ALL persons from vehicle.

•   Shut off gas supply at gas container or source.

•   DO  nOT touch any electrical switch, or use any phone 

or radio in vehicle.

•   DO nOT start vehicle’s engine or electric generator.

•   Contact nearest gas supplier or qualified Service 

Technician for repairs.

•   If you cannot reach a gas supplier or qualified Service 

Technician, contact the nearest fire department.

•   DO nOT turn on gas supply until gas leak(s) has been 

repaired.

–   Installation and service must be performed by a 

qualified installer, service agency or the gas supplier. 

explanation of model number:
oD_____________________ on Demand
          50________________ input in 1000’s btu
                    01__________ Generation
                

cW______ cold Weather Kit

m

 

criticaL inStaLLation warningS

•  Install in recreation vehicles only. RV’s are recreation vehicles  

 

  designed as temporary living quarters for recreation, camping,  

 

  or travel use having their own power or towed by another vehicle.
•  All combustion air must be supplied from outside the RV, and all    
  products of combustion must be vented to outside the RV.
•  DO NOT vent water heater with venting system serving another  

 

  appliance.
•  DO NOT vent water heater to an outside enclosed porch area.
•  Protect building materials from flue gas exhaust.
•  Install water heater on an exterior wall, with access door opening to  
  outdoors.
•  DO NOT modify water heater in any way.
•  DO NOT alter water heater for a positive grounding system.
•  DO NOT HI-POT water heater unless electronic ignition system  

 

  (circuit board) has been disconnected.
•  DO NOT use battery charger to supply power to water heater even    
  when testing.

Do not install close to opening door or under room slide-out where 
the vent or inlet louvers can be obstructed.

USA and Canada – Follow all applicable state and local codes. In the 
absence of local codes or regulations, refer to the current standards 
of:

—  Local codes or, in the absence of local codes, the National Fuel Gas    

 

Code, ANSI Z223.1/NFPA 54 and/or CSA B149.1, Natural Gas and  

 

 

Propane Installation Code.

—  Local codes or, in the absence of local codes, the Standard on  

 

 

Recreational Vehicles, NFPA1192 and/or CAN/CSA-Z240 RV.

CUTOUT Requirements
OEM and Aftermarket – Unit can be installed in Atwood, Suburban and Girard 

openings. Unit can also be installed through the wall from exterior, or prior to 

erecting wall into place at OEM manufacturing facility.
Atwood 6 Gallon Opening 

12.7 H x 16.25 W x 17.62 D

Suburban 6 Gallon Opening 

12.7 H x 12.7 W x 19.2 D

Atwood 10 Gallon Opening* 

15.75 H x 16.2 W x 20.6 D

Suburban 10 Gallon Opening*  16.2 H x 16.2 W x 20.5 D

*Door/Adapter Kit Required

Содержание OD50

Страница 1: ...s Btu 01__________ Generation CW______ Cold Weather Kit m critical installation warnings Install in recreation vehicles only RV s are recreation vehicles designed as temporary living quarters for recreation camping or travel use having their own power or towed by another vehicle All combustion air must be supplied from outside the RV and all products of combustion must be vented to outside the RV ...

Страница 2: ...rmined and is being installed at the OEM prior to erecting the walls NOTE Parts bagged and included with the unit in the box are the corner filler brackets and push on water line connectors 1 Locate the water heater on the floor of the coach at pre determined location The unit must be permanently supported at the same level as the bottom of the sidewall cutout by the floor or a raised floor 2 To i...

Страница 3: ...periodic inspection of product of listed equipment or materials as meeting requirements for Relief Valves and Automatic Gas Shutoff Devices of Hot Water Supply Systems ANSI Z21 22 CSA 4 4 Valve must have maximum set pressure not to exceed 100 psi Install replacement valve into opening provided and designated for this purpose on water heater Installation must conform with local codes or in the abse...

Страница 4: ... COLD PACK OPTIONAL IGN CONT SPARK SENSE WIRING SCHEMATIC GREEN GREEN RED RED PURPLE BROWN BROWN RED RED RED PURPLE RED RED BLUE BLUE LOCKOUT LAMP OPTIONAL MPD 90211 m CAUTION FIRE DO NOT smoke or have any flame near an open faucet GENERAL INFORMATION LP and Water system must be turned on Have gas pressure tested periodically Should be set at 11 inches of water column with three appliances running...

Страница 5: ...warm ranging from 70 F to 90 F it is recommended that the modulating valve adjustment be placed in the MIN position This reduces the gas input of the heater to keep the water temperature from getting too hot with high incoming water temperature Winter Operation During the winter months when incoming water temperatures are cooler ranging from 45 F to 70 F it is recommended to place the modulating v...

Страница 6: ...ulting the trouble shooting guide If problems still persist contact Atwood or an authorized service center Only a qualified technician should do any work involving the gas system A periodic visual check of the burner flames should be done by observing the flame through the peep hole in the heat exchanger There should be blue flame with minimum or no yellow tipping Burner maintenance should be perf...

Страница 7: ...inter summer valve is in the proper position for the temperature of the incoming water 3 Water flow too low for incoming water temperature 5 Be sure there is a battery in the system Never connect the heater directly to a power converter Some converters have circuits that are not pure DC This can cause malfunctions or damage to the heater and is not covered by warranty 6 Be sure that no water mixin...

Страница 8: ...lacement of burner orifices c cleaning or adjustment of burner assembly d cleaning or adjustment of flue e adjustment of pressure relief valve 4 In the event of a warranty claim the owner must contact in advance either an authorized Atwood Service Center or the Atwood Service Department Warranty claim service must be performed at an authorized Atwood Service Center can be found online www atwoodmo...

Страница 9: ... ont pas été réparées L installation et la réparation doivent être effectuées par un installateur qualifié une agence de service ou le fournisseur de gaz Explication du numéro du modèle OD_____________________ À la demande On demand 50________________ Entrée en milliers de BTU 01__________ Génération CW______ Kit de temps froid m AVERTISSEMENTS CRITIQUEs SUR L INSTALLATION À installer dans les véh...

Страница 10: ... y a d autres méthodes approuvées comme celles dans le coffre à bagages ou le boîtier encastré Pour toute question supplémentaire veuillez consulter votre vérificateur sur place votre directeur de compte ou le service à la clientèle Atwood Avant de commencer assurez vous que l emplacement approprié a été déterminé et installé par le FEO avant l érection des murs REMARQUE Les pièces mises en sac et...

Страница 11: ...e l interrupteur en position OFF ROUGE est le courant positif d entrée de 12 V c c VERT est la mise à la terre de 12 V c c BLEU est le signal de verrouillage de 12 V c c positif Voir l illustration de la configuration de commutation type 7 Pour prévenir les fuites d eau calfeutrez soigneusement le pourtour arrière des brides et sur les fentes pliées et perforées Calfeutrez le pourtour de l ouvertu...

Страница 12: ... ouvrez le robinet d eau chaude de l évier de cuisine pendant plusieurs minutes avant d utiliser tout appareil électrique relié au système d eau chaude Si de l hydrogène gazeux est présent vous allez probablement entendre des sons tels que l air qui s échappe par le tuyau au moment où l eau commence à couler 1 Mettre en pression le système d eau en tournant sur la pompe ou la pression d eau de vil...

Страница 13: ...débit dans les robinets et ou des pommes de douche Éliminer les restricteurs pour de meilleures performances 4 Propane pression du système de gaz doit être 11 W C en cours de fonctionnement Assurez vous que les réservoirs de propane comportent beaucoup de gaz et sont correctement régulés Cela doit être vérifié par un technicien agréé Atwood Si le problème persiste s il vous plaît contacter le cent...

Страница 14: ... 90290 LISTE DES PIÈCES DU CHAUFFE EAU DÉPANNAGE La plupart des problèmes sont facilement résolus en consultant le guide de dépannage Si le problème persiste veuillez contacter Atwood ou un centre de service agréé Seul un technicien qualifié devrait effectuer tout travail impliquant le système de gaz Une vérification périodique visuelle des flammes du brûleur devrait être faite en observant la fla...

Страница 15: ...avec le terminal seulement 5 Assurez vous que l alimentation du ventilateur a 12 volts lorsque de l eau coule et qu il n y a pas d obstacles dans le conduit d air 6 Assurez vous que mano contact est clôturé par la vérification la tension à travers des terminaux devrait être de 0 volts si lisant 12 volts vérifient l obstruction de conduite ou l obstruction dans la ligne de sens tuyauterie L eau ne ...

Страница 16: ...rais d essence de téléphone de déplacement d hébergement le manque à gagner ou les dommages matériels Certains États n autorisent pas les exclusions ou les restrictions des dommages accessoires ou consécutifs par conséquent il est possible que les restrictions ou les exclusions précédentes ne s appliquent pas à vous 10 Les garanties implicites se limitent à une période de deux 2 ans Certains États...