HOW TO OPerATe yOUr WATer HeATer

If water heater has not been used for more than two weeks, 
hydrogen gas may form in water line. Under these conditions 
to reduce the risk of injury, open hot water faucet for several 
minutes at kitchen sink before you use any electrical appliance 
connected to hot water system.
If hydrogen gas is present, you will probably hear sounds like air 
escaping through the pipe as water begins to flow.

1)  Pressurize the water system by turning on pump or city   
 

water pressure.

2)  Purge all air from the system by turning on the faucets    
 

until a steady stream of water flows.

3)  Turn on the 12V DC power supply.
4)  Turn on the LP supply at the tank and the manual gas    
 

valve (if installed). The water heater will remain dormant   

 

until a water tap is opened and the heater senses water   

 

flow of at least 0.5 GPM.

5)  Turn on the hot water tap to full open. The heater will fire  
 

up within several seconds and hot water will flow from the  

 

tap in the time it takes to traverse the lines from the heater  

 

to the faucet. (If this is the first usage, you may have to   

 

turn the water on and off several times to purge the LP    

 

gas lines of air.) If the heater fails to light or the lockout   

 

lamp (optional) illuminates, turn the power switch OFF,    

 

then On to reset the ignition control.

6)  To shut off the water heater, shut off the water.
7)  Should overheating occur or the gas supply fail to shut off,  
 

turn off the “On/OF” power switch.

a note about “navy showers” When Dry camping

It is recommended to take a shower just like you would at 
home. That is, leave the water running through the entire 
shower. The hot water system is designed to deliver a 
continuous, comfortable flow of hot water and that’s the way it 
works best.
Shutting off the shower with the showerhead button wastes 
water. Each time this is done, the showerhead “trickles”, filling 
the hot water line with cold water. This cold water has to be 
purged from the line each time the showerhead is turned back 
on. Tests have shown that this will not save water.

GAS VALVE

PRESSURE SWITCH

RELAY

FUSE

ECO

FREEZE

PROX

+ 12V DC

GROUND

COLD PACK

(OPTIONAL)

IGN. CONT

SPARK & SENSE

WIRING

SCHEMATIC

(GREEN)

(GREEN)

(RED)

(RED)

(PURPLE)

(BROWN)

(BROWN)

(RED)

(RED)

(RED)

(PURPLE)

(RED)

(RED)

(BLUE)

(BLUE)

LOCKOUT

LAMP

(OPTIONAL)

MPD 90211

m

 

caution

 FirE

•  DO NOT smoke of have any flame near an open faucet.

General informaTion

•  LP and Water system must be turned on.
•  Have gas pressure tested periodically. Should be set at 11  
  inches of water column with three appliances running.
•  Drain water heater at regular intervals (at least one time    
  during the year).
•  Drain water heater before storing RV for the winter or when  
  the possibility of freezing exists.
•  Keep vent and combustion air grill clear of any    

 

  obstructions.

elecTronic iGniTion mainTenance

•  The water heater comes factory-equipped with a fused    
  circuit board, which will protect the circuit board from  

 

  wiring shorts. If the fuse should activate, the water heater  
  will not operate. Before replacing the fuse, check for a short  
  external to the board. Once the short is corrected, replace  
  the 2 amp fuse with a mini ATO style fuse. Do not install a  
  fuse larger than 3 amps.
•  If the fuse is good and the unit is inoperative, check for    
  excessively high voltage to the unit (more than 14 volts).

Winter operation and Winterizing Water Heater

It is not recommended that you operate water systems in the 
winter. Any freezing of the water heater or other plumbing 
components can cause severe damage that is not covered 
by warranty. 

for extended cold temperature use, contact 

atwood regarding the oPTional freeze Protection Kit.

Winter operation:

1.  Turn off water pump and the power and gas to the heater.  
 

Open the pressure relief valve by lifting the handle to a 90°  

 

position from the normal position. (Summer/Winter valve  

 

should be turned to the “SUMMER” 

 

position horizontal).

2.   Open drain valve that was installed                                   
 

at hot water outlet fitting of heater.

3.  Open at least one hot and cold water tap in the coach.   
 

This should drain the system.

Winterizing Procedure:

                                               

Before storing the system for the winter, the plumbing 
system must be winterized. This can be done by either of the 
following methods:
1.  All water should be drained from the system. To do this,  
 

open one tap at a time using compressed air to purge the  

 

system of all water. Once purged, open the Pressure    

 

Relief Valve and leave in the open position.

2.  Follow recommendations of your coach manufacturer. Use  
 

RV non-toxic antifreeze. 

Содержание MPD 90222

Страница 1: ...Input in 1000 s Btu 01__________ Generation m critical installation warnings Install in recreation vehicles only RV s are recreation vehicles designed as temporary living quarters for recreation camping or travel use having their own power or towed by another vehicle All combustion air must be supplied from outside the RV and all products of combustion must be vented to outside the RV DO NOT vent ...

Страница 2: ...ior to erecting the walls NOTE Parts bagged and included with the unit include corner filler brackets flue screen and cover hole bushing 1 Locate the water heater on the floor of the coach at pre determined location The unit must be permanently supported at the same level as the bottom of the sidewall cutout by the floor or a raised floor 2 To install the unit on carpeting assure the addition of m...

Страница 3: ...MP 12 VDC GAS ORANGE FROM W H 9 Place flue screen from parts bag over end of flue tube Place the access door on the lower flange pins aligning the holes in the bottom of the door Carefully close the top edge of the door being careful to align the flue opening with the flue tube and screw in the fastener Push snap plastic bushing supplied in parts bag into the hole in the door front 10 The applianc...

Страница 4: ...ARK SENSE WIRING SCHEMATIC GREEN GREEN RED RED PURPLE BROWN BROWN RED RED RED PURPLE RED RED BLUE BLUE LOCKOUT LAMP OPTIONAL MPD 90211 m CAUTION FIRE DO NOT smoke of have any flame near an open faucet GENERAL INFORMATION LP and Water system must be turned on Have gas pressure tested periodically Should be set at 11 inches of water column with three appliances running Drain water heater at regular ...

Страница 5: ...0 Gas Inlet Tube 90273 11 Ignition Control 90274 12 Flue Outlet Screen 90275 13 Flue Tube 90276 14 Pressure Switch 90277 15 Blower Assembly 90278 16 Fan Base 90279 17 Flue Hood Assembly 90280 18 Case Assembly 90281 19 Heat Exchanger 90282 20 ECO 90283 21 Plug 90284 ITEM DESCRIPTION PART 22 Orifice 72 45 000 Btu 90285 23 Orifice 71 50 000 Btu 90286 24 Orifice 0 27 55K for PT 3392 Inquire 25 Pressur...

Страница 6: ...is sparking from the probe to the burner Bend ignition wire to adjust to proper gap or contact Atwood or you re nearest authorized service representative 5 Check that there are no cuts or breaks in the wire Align it so that it is not in contact with anything but the terminal 6 Be sure that the power vent fan has 12 volts to it when there is water flowing and there are no obstructions in the flue p...

Страница 7: ...art defective in material or workmanship This warranty includes reasonable labor charges required to remove and replace the part Service calls to customer s location are not considered part of these charges and are therefore the responsibility of the owner 3 This warranty does not cover the following items classified as normal maintenance a adjustment of gas pressure b cleaning or replacement of b...

Страница 8: ...8 intentionally left blank ...

Страница 9: ...ou les fuites n ont pas été réparées L installation et la réparation doivent être effectuées par un installateur qualifié une agence de service ou le fournisseur de gaz Explication du numéro du modèle OD_____________________ À la demande On demand 45________________ Entrée en milliers de BTU 01__________ Génération m AVERTISSEMENTS CRITIQUEs SUR L INSTALLATION À installer dans les véhicules récréa...

Страница 10: ...ompte ou le service à la clientèle Atwood Avant de commencer assurez vous que l emplacement approprié a été déterminé et installé par le FEO avant l érection des murs REMARQUE Les pièces ensachées et venant avec l unité de remplissage comprennent le support de fixation la grille du conduit d air et la douille du trou de couverture 1 Localisez le chauffe eau sur le plancher du véhicule à l emplacem...

Страница 11: ...alve doit avoir un réglage de la pression maximale qui ne doit pas dépasser 100 lb po Installez le remplacement de la valve dans l orifice prévu et désigné à cet effet sur le chauffe eau Adaptateur Installation dans l ouverture d un chauffe eau de 10 gallons standard avec la trousse et l adaptateur pour une grande porte 7 Pour prévenir les fuites d eau calfeutrez soigneusement le pourtour arrière ...

Страница 12: ...ndre le chauffe eau couper l eau 7 En cas de surchauffe ou si l approvisionnement en gaz ne s arrête pas fermer l interrupteur On Off ROUGE est le courant positif d entrée de 12 V c c VERT est la mise à la terre de 12 V c c BLEU est le signal de verrouillage de 12 V c c positif Voir l illustration de la configuration de commutation type BLEU DU CHAUFFE EAU LAMPE DE VERROUILLAGE 12 V c c GAZ ORANGE...

Страница 13: ...igé remplacer le fusible de 2 ampères par un mini fusible ATO Ne pas installer un fusible de plus de 3 ampères Si le fusible est bon et que l unité ne fonctionne pas vérifier si l appareil ne présente pas une tension excessive plus de 14 volts Fonctionnement hivernal et hivernage du chauffe eau Il n est pas recommandé d utiliser les systèmes d eau pendant l hiver Tout gel du chauffe eau ou des aut...

Страница 14: ...e d allumage 90274 12 Grille du conduit d air 90275 13 Tube d appel d air 90276 14 Pressostat 90277 15 Ens ventilateur 90278 16 Base ventilateur 90279 17 Ens hotte du conduit d air 90280 18 Ens du boîtier 90281 19 Échangeur de chaleur 90282 20 ECO 90283 21 Fiche 90284 ARTICLE DESCRIPTION Nº DE PIÈCE 22 Orifice nº 72 45 000 BTU 90285 23 Orifice nº 71 50 000 BTU 90286 24 Orifice 0 27 55K pour PT nº ...

Страница 15: ...e qui évitera son déclenchement Il n y a pas d allumage lorsque l eau est activée le ventilateur est en marche 1 Assurez vous que la soupape de gaz du réservoir est à On qu il y a du gaz dans le réservoir et que la conduite de gaz est complètement purgée d air 2 Assurez vous que le débit d eau est d au moins de 0 5 gal minute 3 Vérifiez si le câble d allumage est branché dans la tour d allumage su...

Страница 16: ...clusions précédentes ne s appliquent pas à vous 10 Les garanties implicites se limitent à une période de deux 2 ans Certains États n autorisent pas les restrictions sur la durée d une garantie implicite par conséquent il est possible que les restrictions précédentes ne s appliquent pas à vous Cette garantie vous accorde des droits légaux spécifiques et vous pouvez aussi avoir d autres droits pouva...

Страница 17: ...r cooler hot water temperatures the modulating valve can be adjusted clockwise toward the MIN position One should use caution not to force the valve adjustment beyond the MAX and MIN points Some factors relating to output performance are 1 City or Park Water Service incoming pressures 2 Obstructions or restrictions in the water system including water bypass valves in vehicles The bypass valve in y...