background image

1

This water heater design has been certified by the Canadian 
Standards Association for installation in recreation vehicles.

 This 

water heater is not for use in marine applications.

service calls & quesTions

 Location and phone numbers of qualified Service Centers can 
be found at our website http:/www.askforatwood.com or call 
866.869.8116 to locate a Service Center.

safeTy alerT symbols

  

Safety Symbols alerting you to potential personal safety hazards.  
Obey all safety messages following these symbols.

  m

 

warning 

m

 

caution

 

avoid possible  

avoid possible 

 

injury or death 

injury and/or property damage

EngLiSH - FranÇaiS

 

•Installation  •Operation  •Maintenance 

  

Effective 9.22.11

literature

 

number

 

MPD 90222

l.P. Gas

on DemanD  

WaTer HeaTer

models

oD45, oD50, oD55

m

 

warning

fIre Or exPlOsIOn

  •   If the information in this manual is not followed 

exactly, a fire or explosion may result causing 
property damage, personal injury or loss of life.

–   Do not store or use gasoline or other flammable vapors  

and liquids in the vicinity of this or any other appliance.

WHaT To Do if you smell Gas 

•   Evacuate ALL persons from vehicle.

•   Shut off gas supply at gas container or source.

•   DO nOT touch any electrical switch, or use any phone 

or radio in vehicle.

•   DO nOT start vehicle’s engine or electric generator.

•   Contact nearest gas supplier or qualified Service 

Technician for repairs.

•   If you cannot reach a gas supplier or qualified Service 

Technician, contact the nearest fire department.

•   DO nOT turn on gas supply until gas leak(s) has been 

repaired.

–   Installation and service must be performed by a 

qualified installer, service agency or the gas supplier. 

explanation of model number:
oD_____________________ on Demand
          45________________ input in 1000’s btu
                    01__________ Generation

m

 

criticaL inStaLLation warningS

•  Install in recreation vehicles only. RV’s are recreation vehicles  

 

  designed as temporary living quarters for recreation, camping,  

 

  or travel use having their own power or towed by another vehicle.
•  All combustion air must be supplied from outside the RV, and all    
  products of combustion must be vented to outside the RV.
•  DO NOT vent water heater with venting system serving another  

 

  appliance.
•  DO NOT vent water heater to an outside enclosed porch area.
•  Protect building materials from flue gas exhaust.
•  Install water heater on an exterior wall, with access door opening to  
  outdoors.
•  DO NOT modify water heater in any way.
•  DO NOT alter water heater for a positive grounding system.
•  DO NOT HI-POT water heater unless electronic ignition system  

 

  (circuit board) has been disconnected.
•  DO NOT use battery charger to supply power to water heater even    
  when testing.

Do not install close to opening door or under room slide-out where 
the vent or inlet louvers can be obstructed.

USA and Canada – Follow all applicable state and local codes. In the 
absence of local codes or regulations, refer to the current standards 
of:

—  Local codes or, in the absence of local codes, the National Fuel Gas    

 

Code, ANSI Z223.1/NFPA 54 and/or CSA B149.1, Natural Gas and  

 

 

Propane Installation Code.

—  Local codes or, in the absence of local codes, the Standard on  

 

 

Recreational Vehicles, NFPA1192 and/or CAN/CSA-Z240 RV.

CUTOUT Requirements
OEM and Aftermarket – Unit can be installed in Atwood, Suburban and Girard 

openings. Unit can also be installed through the wall from exterior, or prior to 

erecting wall into place at OEM manufacturing facility.
Atwood 6 Gallon Opening 

12.7 H x 16.25 W x 17.62 D

Suburban 6 Gallon Opening 

12.7 H x 12.7 W x 19.2 D

Atwood 10 Gallon Opening* 

15.75 H x 16.2 W x 20.6 D

Suburban 10 Gallon Opening*  16.2 H x 16.2 W x 20.5 D

*Door/Adapter Kit Required

Содержание MPD 90222

Страница 1: ...Input in 1000 s Btu 01__________ Generation m critical installation warnings Install in recreation vehicles only RV s are recreation vehicles designed as temporary living quarters for recreation camping or travel use having their own power or towed by another vehicle All combustion air must be supplied from outside the RV and all products of combustion must be vented to outside the RV DO NOT vent ...

Страница 2: ...ior to erecting the walls NOTE Parts bagged and included with the unit include corner filler brackets flue screen and cover hole bushing 1 Locate the water heater on the floor of the coach at pre determined location The unit must be permanently supported at the same level as the bottom of the sidewall cutout by the floor or a raised floor 2 To install the unit on carpeting assure the addition of m...

Страница 3: ...MP 12 VDC GAS ORANGE FROM W H 9 Place flue screen from parts bag over end of flue tube Place the access door on the lower flange pins aligning the holes in the bottom of the door Carefully close the top edge of the door being careful to align the flue opening with the flue tube and screw in the fastener Push snap plastic bushing supplied in parts bag into the hole in the door front 10 The applianc...

Страница 4: ...ARK SENSE WIRING SCHEMATIC GREEN GREEN RED RED PURPLE BROWN BROWN RED RED RED PURPLE RED RED BLUE BLUE LOCKOUT LAMP OPTIONAL MPD 90211 m CAUTION FIRE DO NOT smoke of have any flame near an open faucet GENERAL INFORMATION LP and Water system must be turned on Have gas pressure tested periodically Should be set at 11 inches of water column with three appliances running Drain water heater at regular ...

Страница 5: ...0 Gas Inlet Tube 90273 11 Ignition Control 90274 12 Flue Outlet Screen 90275 13 Flue Tube 90276 14 Pressure Switch 90277 15 Blower Assembly 90278 16 Fan Base 90279 17 Flue Hood Assembly 90280 18 Case Assembly 90281 19 Heat Exchanger 90282 20 ECO 90283 21 Plug 90284 ITEM DESCRIPTION PART 22 Orifice 72 45 000 Btu 90285 23 Orifice 71 50 000 Btu 90286 24 Orifice 0 27 55K for PT 3392 Inquire 25 Pressur...

Страница 6: ...is sparking from the probe to the burner Bend ignition wire to adjust to proper gap or contact Atwood or you re nearest authorized service representative 5 Check that there are no cuts or breaks in the wire Align it so that it is not in contact with anything but the terminal 6 Be sure that the power vent fan has 12 volts to it when there is water flowing and there are no obstructions in the flue p...

Страница 7: ...art defective in material or workmanship This warranty includes reasonable labor charges required to remove and replace the part Service calls to customer s location are not considered part of these charges and are therefore the responsibility of the owner 3 This warranty does not cover the following items classified as normal maintenance a adjustment of gas pressure b cleaning or replacement of b...

Страница 8: ...8 intentionally left blank ...

Страница 9: ...ou les fuites n ont pas été réparées L installation et la réparation doivent être effectuées par un installateur qualifié une agence de service ou le fournisseur de gaz Explication du numéro du modèle OD_____________________ À la demande On demand 45________________ Entrée en milliers de BTU 01__________ Génération m AVERTISSEMENTS CRITIQUEs SUR L INSTALLATION À installer dans les véhicules récréa...

Страница 10: ...ompte ou le service à la clientèle Atwood Avant de commencer assurez vous que l emplacement approprié a été déterminé et installé par le FEO avant l érection des murs REMARQUE Les pièces ensachées et venant avec l unité de remplissage comprennent le support de fixation la grille du conduit d air et la douille du trou de couverture 1 Localisez le chauffe eau sur le plancher du véhicule à l emplacem...

Страница 11: ...alve doit avoir un réglage de la pression maximale qui ne doit pas dépasser 100 lb po Installez le remplacement de la valve dans l orifice prévu et désigné à cet effet sur le chauffe eau Adaptateur Installation dans l ouverture d un chauffe eau de 10 gallons standard avec la trousse et l adaptateur pour une grande porte 7 Pour prévenir les fuites d eau calfeutrez soigneusement le pourtour arrière ...

Страница 12: ...ndre le chauffe eau couper l eau 7 En cas de surchauffe ou si l approvisionnement en gaz ne s arrête pas fermer l interrupteur On Off ROUGE est le courant positif d entrée de 12 V c c VERT est la mise à la terre de 12 V c c BLEU est le signal de verrouillage de 12 V c c positif Voir l illustration de la configuration de commutation type BLEU DU CHAUFFE EAU LAMPE DE VERROUILLAGE 12 V c c GAZ ORANGE...

Страница 13: ...igé remplacer le fusible de 2 ampères par un mini fusible ATO Ne pas installer un fusible de plus de 3 ampères Si le fusible est bon et que l unité ne fonctionne pas vérifier si l appareil ne présente pas une tension excessive plus de 14 volts Fonctionnement hivernal et hivernage du chauffe eau Il n est pas recommandé d utiliser les systèmes d eau pendant l hiver Tout gel du chauffe eau ou des aut...

Страница 14: ...e d allumage 90274 12 Grille du conduit d air 90275 13 Tube d appel d air 90276 14 Pressostat 90277 15 Ens ventilateur 90278 16 Base ventilateur 90279 17 Ens hotte du conduit d air 90280 18 Ens du boîtier 90281 19 Échangeur de chaleur 90282 20 ECO 90283 21 Fiche 90284 ARTICLE DESCRIPTION Nº DE PIÈCE 22 Orifice nº 72 45 000 BTU 90285 23 Orifice nº 71 50 000 BTU 90286 24 Orifice 0 27 55K pour PT nº ...

Страница 15: ...e qui évitera son déclenchement Il n y a pas d allumage lorsque l eau est activée le ventilateur est en marche 1 Assurez vous que la soupape de gaz du réservoir est à On qu il y a du gaz dans le réservoir et que la conduite de gaz est complètement purgée d air 2 Assurez vous que le débit d eau est d au moins de 0 5 gal minute 3 Vérifiez si le câble d allumage est branché dans la tour d allumage su...

Страница 16: ...clusions précédentes ne s appliquent pas à vous 10 Les garanties implicites se limitent à une période de deux 2 ans Certains États n autorisent pas les restrictions sur la durée d une garantie implicite par conséquent il est possible que les restrictions précédentes ne s appliquent pas à vous Cette garantie vous accorde des droits légaux spécifiques et vous pouvez aussi avoir d autres droits pouva...

Страница 17: ...r cooler hot water temperatures the modulating valve can be adjusted clockwise toward the MIN position One should use caution not to force the valve adjustment beyond the MAX and MIN points Some factors relating to output performance are 1 City or Park Water Service incoming pressures 2 Obstructions or restrictions in the water system including water bypass valves in vehicles The bypass valve in y...