background image

Maintenance

22

Fault code or fault description

Likely causes of the faults

E-1

thermal fuse fault

E-2:sensor alarm

E-3:zero-cross detection

abnormal alarm

Shall be sent to the designated after-sales service outlet for maintenance.

E-4:abnormal temperature alarm

In case the heating object loses heat too fast, which cannot reach the set specified

temperature even being heated for a long time. You need larger power soldering

equipment.

1. Use user temperature compensation function to correct the temperature.

2. Replace the heating core with one produced and sent by the original factory.

1. In case there is strong interference source from the outside environment, please

change the application environment or evacuate from the interference area.

2. In case the internal circuit is abnormal, please send the equipment to the

designated after-sales outlet formaintenance.

1. Short circuit occurs inside the heating core.

2. In case short circuit occurs to the internal lead wire of the soldering pencil,please

replace the soldering pencil.

1. In case the external power supply voltage is abnormal, please check if the input

voltage of the product meets therequirements.

2. In case the host of the product is damaged, please send it to the designated after-

sales outlet for maintenance.

1. In case the temperature sensor is abnormal, please replace the heatingcore.

2. In case the soldering head temperature is too high, please cool the iron head and

then restart the equipment.

1. In case the handle is not compatible with this equipment, please replace it with the

handle produced by the originalfactory.

2. In case the internal circuit is abnormal, please send the equipment to the

designated after-sales outlet formaintenance.

In case the problem occurs, you can try to adopt the following measures to solve it.

If the problem still cannot be solved, please return the equipment to the original

factory for inspection.

1. Check if the socket switch ison.

2. Check if there is voltage on the socket.

3. Check if the plug with the power line is loose.

4. Check if the fuse is damaged (if so, please replace the fuse according to the

specifications).

E-5:over-current protection

E-6:abnormal system voltage

E-8: abnormal soldering

Tip temperature

E-9: abnormal soldering

handle status

screen display fault:

inaccurate temperature:

Unreadable code:

1. In case open circuit fault occurs to the heating core, replaceit.

2. In case poor contact occurs to the heating core, unplug and then re-installit.

3. In case the internal connection cable inside the heating core & handle is broken or

heating core connection contact piece is damaged, repair the broken lead wire or

replace the soldering pencil.

4.In case the lead wire inside the 9PIN pencil is disconnected, repair the broken

lead or replace the soldering pencil.

1. In case the heating core is damaged, replaceit.

2. In case open circuit occurs to the lead wire of the Sensor, check the lead wire

of the soldering pencil.

Содержание GT-6150

Страница 1: ...GT 6200 GT 6150 User Manual GT compatible...

Страница 2: ......

Страница 3: ...Technical parameters 7 Description of working interface 8 Operations of temperature setup 10 Quick call the related parameters at certain temperature 11 Opening and close of GT 6200 channels 12 Parame...

Страница 4: ...le materials Keep the product out of children s reach Do not use this product if you are inexperienced or have no sufficient necessary knowledge without the guidance of related personnel Do not use th...

Страница 5: ...ertificate of qualification Power cord Operation manual 1 GT 6150 host 1 1 1 1 1 1 1 1 1 Certificate of qualification 3 5mm grounding receptacle GT 6200 GT 6150 product manual GT compatible GT Y130 ap...

Страница 6: ...0 applicable to precision soldering occasion GT Y130 applicable to conventional soldering occasion Combo D Combo E Combo F Combo G GT Y050 applicable to precision soldering occasion GT Y150 applicable...

Страница 7: ...tool channel 1 Setup menu switch key of the Interface for the soldering tool channel 1 Confirm key Menu key Up arrow key minus key Rapid temperature key 2 System setup menu switch key Rapid temperatu...

Страница 8: ...nection steps for the whole equipment 6 Note To avoid the damage to the host do not forget to turn off the power when inserting the plug into or removing the plug from the soldering tools 1 1 2 2 1 2...

Страница 9: ...e which can be called quickly 240x160 Dots white letters on blue Temperature 0 40 Relative humidity 80 Temperature 20 80 Relative humidity 80 Approximately 4kg 315 L 252 W 127 H mm English Chinese Pow...

Страница 10: ...s abnormal code Status display area of channel 2 display power bar product working status abnormal code Actual temperature display area of channel 2 display of the indicative description of abnormal w...

Страница 11: ...er the screen display System verion for 3 seconds Status display area of channel 1 display power bar product working status abnormal code Channel 1 rapid temperature 3 Fixed temperature icon display S...

Страница 12: ...eds to be configured GT 6150 is not equipped with such channel Press UP arrow key to increase the temperature Press DOWN arrow key to decrease the temperature 8 50 50 c o GT Y050 200 300 400 00 50 50...

Страница 13: ...ey to quickly call the set value at 200 Short press the 2 key to quickly call the set value at 300 Likely short press the 3 key to quickly call the set value at 400 Note Rapid temperature value can be...

Страница 14: ...d close of GT 6200 channels 12 Long press 1 key to open or close channel 1 Long press 3 key to open or close channel 2 50 200 50 c o GT Y050 200 300 400 GT Y050 8 200 50 c o 200 300 400 GT Y050 GT Y05...

Страница 15: ...to return to the main interface If there is no password protection or after the correct password is entered it will jump to the System Parameter setup interface At this time the system parameters can...

Страница 16: ...t to the factory settings Exit Press to return to the main interface Used to set the system Language EN English CN Chinese The factory fault is English Total items of parameter setup menu of the host...

Страница 17: ...the Parameter setup of the channels for the handle to carry out lockup operation on the whole equipment for welding processcontrol The factory default mode OFF When the system is under the password s...

Страница 18: ...s After clicking the State as delivered key all the system setup parameters and channel parameters will be resumed to the factory default settings Note This is only applied to those parameters corresp...

Страница 19: ...Temp3 Available for users to quickly call the set temperature 3 Fix Temp After this mode is activated the output temperature is locked at this set temperature value Temp UL the highest temperature tha...

Страница 20: ...e temperature compensation value to 15 27 F to compensate the error of the output temperature When the handle is under the standby mode the maintaining temperature is 150 C 302 F the lowest standby te...

Страница 21: ...will not enter into the dormancy state if the standby mode is not activated The factory default is OFF A total of 3 sets of temperature data are available for users to quickly call subject to the Tem...

Страница 22: ...The configurable minimum temperature is 150 C 302 F The configurable maximum temperature of the Temperature lower limit shall be less than the Temperature upper limit value The factory default value...

Страница 23: ...protective ground wire of the power line After the 3 5mm plug is inserted the ground wire of the soldering tool handle is connected to the 3 pins of the 3 5mm plug When the 3 5mm plug is connected to...

Страница 24: ...he soldering head temperature is too high please cool the iron head and then restart the equipment 1 In case the handle is not compatible with this equipment please replace it with the handle produced...

Страница 25: ...e free of charge For those product beyond the warranty period we provide life long maintenance services For those product damaged due to users improper application and unauthorized changes to the prod...

Страница 26: ...uminum Press plate Interface panel Panel Interface board PCB Self adhesive foot pad Transformer Bottom shell Power board PCB Public seat Fuse Power cable Right decorative plate Left decorative plate T...

Страница 27: ...within the guarantee period we will response for the maintenance free of charge on presentation of this card and the receipt We will repair and return the repaired equipment to the customer within 2 w...

Страница 28: ...right Reserved MADE IN CHINA CBN029642 A Soldering iron Soldering station Hot air rework station Multi function maintenance system Regulated DC power supply Switching DC power supply Programmable powe...