Parameter setup menu of the channels for the handle
18
Standby Delay
Channel1 Set
〉
Standby Delay
Standby Temp
Channel1 Set
〉
Standby Temp
Temp Offset
Channel1 Set
〉
Temp Offset
Used to compensate the errors of welding pencil
temperature output.
Compensation range: -50
℃
~ +50
℃
,-90
℉
to +90
℉
.
When the value is positive, the handle temperature will
increase according to the set value; when the value is
negative, the handle temperature will decrease
according to the set value.
The factory default value is : 0.
When replacing the heating element or the handle, the temperature if not accurate, can be calibrated by changing the
following parameter.
Operation is as follows:
1. Set the to-be-calibrated temperature of the handle to a suitable temperature, such as 350° C / 662 °F.
2. After the temperature is stabilized, use the thermometer to measure the actual temperature of the soldering tip of
the current handle, for example, the actual temperature is measured as 365
℃
/ 689
℉
.
3. Through the analysis, it is concluded that the actual current temperature is 15
℃
/ 27
℉
higher than the set temperature.
4. Set the temperature compensation value to -15
℃
/ -27
℉
F to compensate the error of the output temperature.
When the handle is under the standby mode, the maintaining
temperature is:
150 ° C / 302 ° F: the lowest standby temperature.
300
℃
/ 572
℉
: the highest standby temperature value.
When the set actual operating temperature is less than the set
standby temperature, the product will enter the standby mode with
the actual operating temperature.
The factory default is: 150.
The product automatically enters into the standby state based on the set
delay value (unit: minute) if the handle is idle for a long time:
1 ~ 120: The product's dormancy mode will be activated, and enters into
the dormant state based on the stipulation time.
OFF: The handle will not enter into the dormancy state.
When the set actual operating temperature is less than the set standby
temperature, the product will enter the standby mode with the actual
operating temperature.
The factory default is: OFF.
Channel1 Set
GT-Y050
0
Standby Temp
150
Standby Delay
OFF
Shutdown Delay
OFF
Shortcut Temp1
200
Temp Offset
Channel1 Set
GT-Y050
0
Standby Temp
150
Standby Delay
OFF
Shutdown Delay
OFF
Shortcut Temp1
200
Temp Offset
Channel1 Set
GT-Y050
0
Standby Temp
150
Standby Delay
OFF
Shutdown Delay
OFF
Shortcut Temp1
200
Temp Offset