35
35
Signal Generator
10.0000 kHz will appear below the
AM Rate
soft function key.
3-2-4 Run amplitude modulation
The signal generator is now configured as a carrier wave that outputs 0dBm and
performs amplitude modulation at 1340 kHz; the AM modulation depth is set as
90%, and the AM modulation rate is set as 10 kHz. The waveform is sine wave
(please note that the sine is a default value of the
AM waveform
soft function key.
The amplitude modulation signal is output according to the following steps:
1. Press the
MOD Off On
key.
At the moment, the MOD ON indicator is activated to show that the modulation
on-off is run.
2. Press
AM Off On
soft function key.
AM will be switched from Off to On . Please note that AM display indicator will
be opened to point out that you have already run amplitude modulation.
3. Press the
RF On Off
key on the front panel.
At the moment, the RF ON indicator is activated, which proves that the signal
can be acquired from the RF OUTPUT connector.