MAN - RTFO - REV: Org | H. Maintenance
20
H. Maintenance
H.1 Cleaning the Unit
Before cleaning the RTFO, unplug the machine and allow it to cool. Always wear personal protective gear and clean
using Acetone. Do not use any other flammable solvents to clean this machine. Allow equipment to sit, with door
open, for a minimum of 15 minutes before further use to allow any vapors from the cleaning solvent to dissipate.
WARNING: Do not use flammable solvents other than what is specified.
WARNING: Using solvents or products not specified by the equipment manufacturer may create
potential for formation of flammable or volatile gas mixtures. Always refer to product SDS or
contact the manufacterer.
H.2 Replacing Damaged Cables
A qualified person should perform the replacement of any cable. Replacement cables shall be of like kind, size,
rating, and specification, as originally supplied by the manufacturer. Use of cables not meeting original specifications
may result in injury to personnel, improper operation, damage to equipment, and void warranty.
H.3 Bearing Service and Replacement
The two shaft bearings that support the carousel wheel are sealed, non-servicable bearings. In the event of bearing
failure, contact the ATS Service Department at +1-724-283-1212.
To remove bearing assembly:
1. Place Main Power Switch in “OFF” position and disconnect power.
WARNING: Electrical shock hazard. The heating elements remain electrically live when the Main
Power Switch is in the “ON” position. Always remember to place the Main Power Switch in the
“OFF” position and disconnect power before performing any maintenance.
WARNING: Finger crush hazard. Ensure machine operation has been disabled before removing
rear cover.
2. Remove the air coil and tray by disconnecting the air line at the coupling (Fig. H.1), remove the retaining screw (Fig.
H.2), and slide the tray out of the RTFO (Fig. H.3).