Perfomance Data Sheet
Model Number . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . DWS-8C Class A
Rated Service Flow . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 gallons / minute
Maximum Working Pressure . . . . . . . . . . . . . . . . . . . . 100 psi
Maximum Operating Temperature . . . . . . . . . . . . . . . . 110ºF
UV Monitor-
The UV Monitor has built-in alarms to warn of inefficient performance or UV lamp failure. When the UV intensity
measured by the UV Monitor and Sensor falls below the preset alarm condition (70%) to notify the user that the UV
Lamp requires replacement. The alarm will sound and the LED display will flash.
For general installation, operation and maintenance instructions and use limitations please see the Installation and
Operation Manual for the DWS-8C Class A System.
For applications-
This Class A system conforms to NSF/ANSI 55 for the disinfection of microbiologically contaminated water that meets
all other public health standards. The system is not intended to convert wastewater or raw sewage to drinking water.
The system is intended to be installed on visually clear water.
NSF/ANSI 55 defines wastewater to include human and/or animal body waste, toilet paper, and any other material
intended to be deposited in a receptacle designed to receive urine and/or feces (blackwaste); and other waste materials
deposited in plumbing fixtures (greywaste).
If this system is used for the treatment of untreated surface waters or ground water under the direct influence of
surface water, a device found to be in conformance for cyst reduction under the appropriate NSF/ANSI Standard shall
be installed upstream of the system.
Electrical Characteristics ..............................................................................120V/60 Hz 0.6 amps
Recommended Service Life of UV Lamps ..................................................9,000 hours
Maximum Operating Feed Water Temperature ............................................110ºF
Model Number of Replacement Components ..............................................ATS8-246 UV Lamp
Minimum Working Pressure .........................................................................25 psi
Minimum Operating Temperature ................................................................35ºF
Electrical Requirements ................................................................................120V/60Hz 0.6 amps
Recommended Replacement Intervals of UV Lamps ..................................9,000 hours