TROUBLESHOOTING GUIDE
PROBLEM
CAUSE
CORRECTION MEASURE
Unit will not initially come on
Electrical connection.
Check line voltages 110-120V AC.
Failure to meter safe initially or
Air obstruction.
Vertical mounting of the U.V..
during operation.
O-Ring obstruction.
Do not overtighten sight port
nut-
hand
tighten
only.
Quartz disc obstruction
Dry seal between disc
or impairment.
and probe.
Physical
obstruction
between
quartz
and
probe.
Dirt or stain build-up on lens.
Clean
with
denatured
alcohol.
Bulb temperature too high.
Run water to nearest drain
> 140° F.
through U.V. to allow the unit
to reach optimum temperature
for the U.V. bulb (104° F.).
Ballast temperature
Check ballast temperature.
too extreme.
If greater than 160°F,
replace
ballast.
Impaired quartz sleeve.
Clean and/or replace.
U.V. bulb output too low.
Replace. You will not be able to
measure
this
output.
If corrective measures have been taken and no apparent results occur, please call the Factory for more
information. Phone: (717) 697-4998.