Chapter 6 Appendix Information
6.1
Fault repair
1.
Phenomenon: No voltage output, all display lights on the panel are off.
Reason: No power input
Exclusion:
A
, check switch is turned on.
B
, check the fuse is blown.
C
, the input power is properly plugged into the socket or power outage.
2.
Phenomenon: No voltage output, frequency meter display flashes, voltage display
"0"
and buzzer sound
Causes:
A
, overload or abnormal load.
B
, the load starting current is too large.
Exclusion: Turn off the switch, press
ON / OFF,
after reducing or checking the load, just turn on the output switch.
3.
If there is a failure that cannot be eliminated, please notify the maintenance department of our company, and we
will do good after-sales service for you.
6.2
Product maintenance
1.
The quality guarantee period of this product is twelve months, during which non-human faults can be guaranteed
free of charge.
2.
If the quality guarantee period is exceeded, only Victoria's cost will be charged.
3.
Long-term tracking and service, and establish files for customers.
4.
Can undertake customized batches and special specifications.
6.3 APS5000A
series product communication protocol
Agreement
1
Instruction list:
Integer Reader Command
instruction
Parameter range
Explanation
?MAXPOW
Machine power
?MAXVOL
Maximum voltage of the machine
?MAXCUR
Maximum current of the machine
?MAXFRE
Maximum frequency of the machine
?MINFRE
Machine minimum frequency
? MODEL
Read machine model