LED
indicator flashes. If you press the first button to clear the buzzer alarm, press the second button to reset the error
message and restore the output.
5.9
M1. M2. M3. M4. M5
Five groups of memory modes
(
three groups for
APS5000A
series) can store the setting state of voltage and
frequency in any group of memory modes. To memorize, press and hold any key of
M1
,
M2
,
M3
,
M4
,
M5 for
more
than one second, the indicator flashes, then it can be stored in the memory. To call / click any one
of
M1
,
M2
,
M3
,
M4
,
M5
You can call the stored memory condition.
5.10
Setting of system parameters
In the OFF standby state, press the "SYSTEM" button on the panel to enter the parameter item setting, press the
"eight" or button to change the selection of the item setting (APS4000A series can be changed by turning the knob left
and right Select), press the "SYSTEM" button will turn to the next parameter setting item, as shown below:
The baud rate, communication protocol, and communication address settings are invalid for the APS4000 series. For
communication, please select the APS5000A series
Show small
content
Description of content
Set the baud rate, use the up and down keys to change the setting, in
order:
2400
,
4800
,
9600
,
19200
,
38400
Press
K to
set
K,
Lake to open,
PFF "to
be off, and
F to F to
only
"ON / OFF " ,
and
"
SYSTEM "
button.
Power-on output state setting, "
off"
means no output, "
ON"
means automatic power-on output,
and
"last"
means the last state
Communication protocol selection, use the up and down keys to change the setting
"0"
to close the
communication function,
ASCII
protocol
, "2"
to
Hex
protocol
Not yet developed
Output delay setting, use the up and down keys (knob) to change the setting (in seconds)
Communication address setting, use the up and down keys (knob) to change the setting
a
1-30
w
Precautions:
• Before using this instrument, please read this operating manual carefully and completely.
• The instrument must use a power cord and output cord that meet the rated voltage and current standards.
• The input and output cables of the instrument must be in good contact to avoid fire due to poor contact.
• The instrument is prohibited to be used in flammable, explosive or corrosive environments.
• The instrument must be operated within the range that the operator can monitor. The power supply should be cut off
when there is no personnel monitoring to ensure the safety of personnel and property.
• Connect the load to the output terminal, and confirm that everything is correct before turning on the power output
switch.
• the machine with overload or short circuit protection device to protect the circuit when the overload or short circuit
immediately starts (the machine automatically cut off the power supply output, an alarm buzzer sound and the alarm
indicator light,), the first output switch OFF, to check whether the use of overloading . (If there is overload, please
reduce the load) Reset again. After everything returns to normal, confirm that it is correct before you can continue to
use it.