- 7 -
Important: Installation and ventilation laws, and codes are very different,
you should state and comply with all codes of the National Fire Protection
Association Inc when it comes to requirements for installation of equipment;
Screw 4 adjustable stainless steel legs in the tapping hole with four corners
of the charbroiled bottom, ensure sufficient space for ventilation;
Adjustable stainless steel legs to make the equipment level, and get the same
level with other series of the same stove; Please lift the equipment rather
than drag if you need to move it;
Supplied gas pressure regulator is factory set at 4”Natural Gas W.C, and
10”L.P. Gas W.C;
The equipment can only be placed on the incombustible counter top, and keep
a distance of at least 6 inches(152mm) to equipment’s both sides and back,
and keep a distance of at least 4 inches(102mm) to the bottom;
Do not put anything around the equipment, and on the counter top and bottom,
in order to avoid influencing combustion and air circulation;
Leave enough distance in front of the equipment to take apart the control
panel. All major parts, in addition to the burner remove from the front
intake-tube;
It may be necessary to adjust the balance of air input by authorized and
licensed technicians;
Thread glue must be resistant to the action of liquefied petroleum gases.
Warning! Use soap water or testing instrument to test whether piping joint
leaks or not before using, and forbid using an open flame to test!
After installing completely, you should check gas supply pressure. Use a
pressure gauge which is equipped with liquid
(such as U-type pressure gauge, the minimum
value is 0.1mbar) or a digital pressure gauge
to test. Steps are as following:
●Remove top panel, and needle type
pressure joint screw arbor (Fig.1), then
slip rubber tube of pressure gauge over
needle type pressure joint;
●Start the equipment in accordance with
the instructions, measuring gas supply
pressure (dynamic pressure) in the work state;
Fig.1
●Access to the equipment if measured data within the limits of Table
1, otherwise, you will need to adjust gas pressure regulating valve
or contact gas supplier to bargain;