- 12 -
<Table 2>
Items
Methods
Times
Body
Wipe it with a soft cloth and mild
detergent;
daily
Control panel
Turn off valves when not in use;
Wipe panel and control valve knob with
mild detergent.
daily
Catch tray
Pull out catch tray from front body until
the equipment cools down. Use a cloth with
cleaning agent to wipe unit surface, wipe
up residue. Reinstall after cleaning.
Warning: if the catch tray is permitted
to fill too high, should be cleaned!
Per use
10.
Troubleshooting
<Table 3>
Problems
Possible causes
Problem solving
Not lighting
1.Insufficient gas pressure
in pipe
1.Contact the local
gas supply dept.
2.Nozzle occlusion
2.Dredge nozzle
Ignite
the
pilot
light
but not the
main fire
1.Insufficient gas pressure
in pipe
1.Contact the local
gas supply dept.
2.The
main
fire
nozzle
occlusion
2.Dredge nozzle
3.Gas control valves have
problems
3.Change
gas
control valves