DESCRIPTION OF THE ADJUSTMENT AND MAINTENANCE OPERATIONS
WASTE PRODUCTS
During the machine operation following waste products result:
∙
brake shoe dust, exhaust fumes
∙
condensate
Warning
Do not breathe these substances!
Condensate should be stored and disposed according to applicable laws.
Pay attention to sufficient ventilation of exhaust fumes and access of air for the cooling system.
Following materials which, if used improperly, can be harmful to health have been used to build the machine:
∙
compressor oil,
∙
engine oil,
∙
preservation grease,
∙
anti corrosive coatings,
∙
diesel oil,
∙
battery electrolyte.
Warning
Prevent contact of these materials with skin and do not inhale the vapours!
After contact with eyes, immediately flush them with running water for at least 5 minutes.
After contact with skin, wash it immediately.
In cases of ingestion, seek medical help immediately.
When inhaled excessive amount of the substance, seek medical help immediately.
Never give fluids to a victim in convulsions, try to induce vomiting.
These safety instructions are taken from manufacturers of these substance.
Do not operate the machine inside a building without sufficient ventilation. Do not inhale exhaust fumes when working with
or near the machine.
This machine contains substances such as oil, diesel oil, antifreeze, brake fluid, oil/air filters and batteries. Special measures
should be taken during maintenance and repairs. These substances should be disposed according to local regulations.
EXCHANGE OF SUSPENSION EQUIPMENT
For coupling to the towing vehicle it is possible to use interchangeable front part of a tow bar - an eye Ø40 mm (or Ø50 mm)
or a hitch ISO 50 mm.
Warning
According to the valid Technical approval the exchange of this part can be carried out by the manufacturer or
its authorized workshop only. For the exchange only prescribed connecting materials should be used and the
prescribed tightening moments should be kept. New self-securing nuts should be used for every exchange.
At 2020/N
X.11.2016
32