
Operation and Maintenance Manual - EN
EN
www.atmos.cz
EN-11
•
The safety thermostat
- located on the fuel supply pipe of the burner, will shut down the burner
if its temperature is higher than 95 °C. Thus, it protects the burner from return ignition of pellets
in the conveyor and at the same time from operation with clogged flue gas exhaust from the boiler
(e.g. in case of a failure to remove dust from the boiler, flue gas duct and chimney). The safety
thermostat will also put the burner out of operation in case the hose between the burner and
conveyor gets perforated to prevent flue gas from escaping to the boiler room.
INFO
- After any shutdown of the burner when an error message (ALARM) appears on
the display it is necessary to immediately find the cause and remove it. After removing the
cause of the error you can start the burner by merely
turning off and on the burner switch
,
which is located on the boiler panel.
Basic dimensions of the opening for installation of the burner in a boiler
In the case of the D80P, P80 boilers the boiler comprises a frame with a sealing cord - 18x32 mm.
Explanatory notes:
1. A85 burner
2. Sealing
3. Screw - M10
4. Decorative nut - M10
Содержание A85
Страница 1: ...Operation and Maintenance Manual EN www atmos cz Operation and Maintenance Manual ...
Страница 2: ...www atmos cz Operation and Maintenance Manual EN ...
Страница 61: ...Operation and Maintenance Manual EN EN www atmos cz EN 61 20 Expanded view of the burner ...
Страница 66: ...EN www atmos cz 66 EN Operation and Maintenance Manual EN Notes ...