Read the section ‘WARNING ‘first.
Test the “ELSD” regularly
Turn on the electricity (
G
) and water supply (
J
), the green ELSD
lamp (
F
) will light up. If the temperature control knob (
E
) is in ‘ON’
position; the red heater lamp will light up also.
Press The ELSD test knob (
B
), the ELSD and heater lamp should
go off. Press the reset knob (
C
) to resume the electricity supply.
If the ELSD or heater lamp does not go off when you press the
ELSD test knob, SWITCH OFF the main supply and contact
service. NEVER try to repair the unit by yourself.
The users shall test the built in ELSD at least once a month to
ensure the heater is safe to use.
Clean the filter
Remove the filter by turn it anti clockwise and flush it with water to
remove any trapped Sediments.
Fitting and cleaning the Shower head
Warning: Metallic / chromed hose and conductive control
valve shall not be used. (Apply for products installed in
Malaysia only)
•
Fit the two end brackets to the Rod.
•
Place the brackets with rod onto the wall and mark the position
on the two screw holes.
•
Fit the end brackets, holder and rod onto the wall with the wall
plugs and screw provided.
•
Fit the flexible hose to the shower head.
•
Connect the flexible hose with shower head to the heater using
the rubber sealing washer.
•
Place the shower head in the holder.
•
The heater is now ready to be fitted to the electrical supply.
Note: The shower head must be periodically clean to ensure no
blockage occurred.
Do not use thinner, alcohol, petrol or any other organic solutions
to clean the set.
Maintenance