background image

Hot Water

 

on Demand

12

www.atmor.net

Trouble shooting

SYMPTOM

POSSIBLE CAUSE

SOLUTION

Water no! hot 

enough

Too much waler fIowing through 

the heater

Reduction In tha ambient 

temperature

Water Pressure below of 1.0bar

Electrical Mallunction

Reduce the flow rate of the waler via 

the outlet tap.

Switch to higher temperature setting.

Check if the mains stop valve is fully 

open and that the there are no other 

restriction in the supply line.

Have the Heater unit check by a 

qualified eIectrician or contact your 

local authorised distributor.

Water too hot

Not enough Water flowing through 

the heater

Increase in the ambient 

temperature

Increase the flow rate via the outlet tap

Switch to lower temperature setting

Heater switch Off 

during use

Interruption of mains electrical 

supply

ELSD trip, possible earth leakage

Check incoming power supply, MCB, 

switches and supply cabling. Check 

earth leakage and reset ELSD

If problem persists, call your local 

authorised distributor for assistance.

Water ceases to 

flow

Blockage of spray head, twisted or 

blocked flexible shower hose.

No water supply.

Clean or replace sprayheed, check for 

free passage of water through hose. 

Replace as necessary.

Check water supply, stop valve Open? 

and no blockage.

Water 

temperature 

varies from hot to 

cold during use

Water pressure has dropped 

below min. level.

Increase hot water supply,

No hot water 

despite fully open 

hot water faucet

No electrical power

The activation flow rate needed to 

turn on the heating element has 

not been reached.

Check the circuit breaker and check 

voltage at the wiring block.

Clean filter screen

• Turn circuit breaker off

• Open hot valve to release pressure 

from the unit.

• Turn circuit breaker on.

Содержание 100 Series

Страница 1: ...d Operation Guide ATMOR 100 Series Models 100 100V 101 101V 101P 101PV 102 102V 102P 102PV Instant hot water heater provides endless supply of hot water while significantly conserving energy and water www atmor net P N 000000 Reset Pump ...

Страница 2: ...Hot Water on Demand 2 Dear Customer Thank you for purchasing Atmor instantaneous water heater High energy efficiency Slim design Flow controlled ...

Страница 3: ...y or mental capabilities or lack of experience and knowledge unless they have been Using Double Pole ELSD For Phase and neutral Optional Single Pole ELSD Technical data For technical characterizes please refer to the appliance Data sticker Without pump With pump Model 1 9 kg 2 3 kg Weight 381 H 215 W 77 D mm Dimensions WARNING Earth Led Blue indicate the product properly grounded to protect from e...

Страница 4: ...r It is recommended the top of the portion with the top of the heater Remove the terminal cover from the mounting terminal and screw the mounting to position Close the cover Insert the shower holder and soap Tray Close the cover 1 For the correct size of wire conductor corresponding to different electrical loading please refer to table 1 2 The built in ELSD will automatic cut off the power supply ...

Страница 5: ...the stop valve 1 2 BSP 3 Connect the PVC hose and hand shower to the outlet of the heater be sure to put in the rubber washer 4 Hook the hand shower to the slider Rail Holder and adjust to your ideal position THE WATER INLET AND OUTLET MUST BE INSTALLED CORRECTLY OTHERWISE THE HEATER CAN NOT FUNCTION DO NOT USE PLUMBING CEMENT ON CONNECTION IF NECESSARY USE ONLY THREAD OR SEALING TAPE Turn on the ...

Страница 6: ...an only from rear 3 Connect the cable to terminal block and fully tighten them insure no cable insulation is trapped under the screws as follow fig 5 BROWN or RED FOR LIVE L BLUE or BLACK for NEUTRAL N GREEN or Green Yellow for EARTH The cable clamp must be used to secure the cable fig 6 4 Check the wiring connection is tightens and correct then close the front cover When close back the front cove...

Страница 7: ... high In this case you can adjust the water inflow in order to get the desired showering temperature 5 Check the Built in ELSD as follow Press the TEST button B the unit should trip and cut off the power supply All leds lamps should light off 6 Press the RESET button C the unit should resume normal function Green LED lamp should light on If the above mentioned procedures prevail the ELSD is functi...

Страница 8: ... filter by turn it anti clockwise and flush it with water to remove any trapped Sediments Fitting and cleaning the Shower head Warning Metallic chromed hose and conductive control valve shall not be used Apply for products installed in Malaysia only Fit the two end brackets to the Rod Place the brackets with rod onto the wall and mark the position on the two screw holes Fit the end brackets holder...

Страница 9: ...3 9 22 9 4 6mm2 6 5kW 29 5 28 2 27 0 4 0 6 0mm2 Wattage Amperage AMPs Cable Size mm2 1Ø 220V 1Ø 230V 1Ø 240V 7 5kW 34 1 32 6 31 3 4 0 6 0mm2 8 5kW 38 6 37 0 35 4 6 0 10 0mm2 9 5kW 43 2 41 3 39 6 6 0 10 0mm2 3Ø 220V 3Ø 230V 3Ø 240V 8 5kW 12 9 12 3 11 8 2 52 9 5kW 14 4 13 7 13 2 2 52 Table 1 Electrical Loading Table Wiring Diagram With Pump Power Pump 2P ELSD Control PCBA Power Pump SV 2P ELSD Contr...

Страница 10: ...Hot Water on Demand 10 Wiring Diagram Without Pump Electrical connection ...

Страница 11: ...Hot Water on Demand 11 Part List Terminal Block PCBA DP ELSD Optional SP ELSD PUMP Model Cover ELSD Cover Cover SP Tank Assy Main PCBA Control Pump Flow Switch Assy Inlet Outlet Reset Pump Reset Reset ...

Страница 12: ...terruption of mains electrical supply ELSD trip possible earth leakage Check incoming power supply MCB switches and supply cabling Check earth leakage and reset ELSD If problem persists call your local authorised distributor for assistance Water ceases to flow Blockage of spray head twisted or blocked flexible shower hose No water supply Clean or replace sprayheed check for free passage of water t...

Отзывы: