After the first color light is commissioned, the color scene controller may be brought to the second color light, where 
after, receiving the network parameters, it will not start the network once again, but will join the existing network as 
another router. The subsequent color lights are commissioned in the same way. 

3.3.3.1 

Several color scene controllers in a network 

A Light Link network may contain more than one color scene controller. Additional controller devices are added using 
touch link, which happens between two color scene controllers:  

 

 Bring a factory new color scene controller to a color scene controller that is already in the network, and press 

the PWR button on both devices for more than three seconds 

 

 Perform touch link between the new color scene controller and each of the color lights 

 

 Use any of the controller devices to manipulate color lights 

Note: 

 

If touch link between controller devices is not performed, pairing a new controller device with a color light that is 
already in the network, will cause the color light to leaving this network, and form a new one. 

3.3.4  Controlling a light device – all commands 

Figure 3-2

 on the next page depicts the key remote board’s keyboard and all commands that can be sent with the 

buttons from the color scene controller. 

Each button may be used to send up to four commands. What command is sent by pressing a button, depends on 
whether buttons R+ and R- are also pressed or not as shown in 

Table 3-2

Table 3-2.  Alternating a command by holding R+ and R- buttons. 

Number of command 

R+ and R- buttons state 

First command 

Both are not pressed 

Second command 

R+ is pressed, R- is not pressed 

Third command 

R+ is not pressed, R- is pressed 

Fourth command 

Both are pressed 

For example, to send a Toggle command press the L+ button while holding both the R+ and R- buttons pressed. 

For buttons 1, 2, and 3:

 if a button is pressed for more than three seconds (when both R+ and R- are not pressed) a 

Store Scene command is sent; if a button is pressed for less than three seconds a Recall Scene command is sent. 

Содержание AVR2060

Страница 1: ...of the BitCloud ZigBee Light Link software development kit SDK a software package for developing ZigBee Light Link profile applications Chapter 1 gives an overview of the software package and support...

Страница 2: ...6 2 3 1 1 Precompiled images 6 2 3 1 2 Application workspace 6 2 3 2 Programming with Atmel AVR Studio 6 3 Demo application 7 3 1 Launching the demo 7 3 2 Color light s functions 7 3 2 1 Touch link wi...

Страница 3: ...ific API definitions BitCloud lib BitCloud compiled libraries Applications ZLLDemo Demo application s sources and projects Evaluation Tools ZLLDemo Demo application s pre compiled images Documentation...

Страница 4: ...s used with BitCloud may be found in 3 or 4 2 2 Hardware configuration 2 2 1 Assembling devices Both color scene controller and color light use RCB128RFA1 RCB as a base board For a color scene control...

Страница 5: ...d fuse bits settings are shown in Table 2 1 Table 2 1 Fuse bits for Atmel ATmega128RFA1 Option Required value for 8MHz Required value for 16MHz BODLEVEL 1V8 1V8 OCDEN Enabled Enabled JTAGEN Enabled En...

Страница 6: ...n a workspace for example ZLLDemo eww and select JTAGICE mkII Fuse Handler JTAGICE 3 Fuse Handler 2 Click Read Fuses and make sure that the device fuses are set as specified in Section 2 2 2 3 If fuse...

Страница 7: ...lor light are needed More devices lights or controllers may be added as required Assemble devices as described in Section 2 2 1 Program devices with pre built images of the demo application via JTAG a...

Страница 8: ...ify command to the color light which blinks several times with its LEDs or the LCD screen The touch link procedure may be aborted at this moment if the PWR button is released To complete the procedure...

Страница 9: ...all scene if pressed for less that three seconds 7 8 9 Set minimum middle maximum light level 4 Triggers network update the color scene controller applies a standard ZigBee mechanism to select a new o...

Страница 10: ...te If touch link between controller devices is not performed pairing a new controller device with a color light that is already in the network will cause the color light to leaving this network and fo...

Страница 11: ...ene E Add Scene Remove Scene Store Scene hold Recall Scene Add Scene E Add Scene Remove Scene 4 5 6 Network Update Read ZLL version Trigger Breathe Trigger Finish Trigger Stop 7 8 9 MoveToLevel MoveTo...

Страница 12: ...by color light and color scene controller Such file initializes structures needed for the cluster and implements callback functions that are called to indicate commands responses For example see the...

Страница 13: ...ght Link Profile Specification Version 1 0 2 AVR2056 BitCloud Profile Suite Developer Guide 3 AVR2052 BitCloud Quick Start Guide 4 AVR2055 BitCloud Profile Suite Quick Start Guide 5 AVR2104 RF4CE EK R...

Страница 14: ...y this document or in connection with the sale of Atmel products EXCEPT AS SET FORTH IN THE ATMEL TERMS AND CONDITIONS OF SALES LOCATED ON THE ATMEL WEBSITE ATMEL ASSUMES NO LIABILITY WHATSOEVER AND D...

Отзывы: