background image

AT-GAIN-120

7

FCC Statement

FCC Compliance and Advisory Statement: This hardware device complies with 

Part 15 of the FCC rules. Operation is subject to the following two conditions: 1) 

this device may not cause harmful interference, and 2) this device must accept any 

interference received including interference that may cause undesired operation. This 

equipment has been tested and found to comply with the limits for a Class A digital 

device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide 

reasonable protection against harmful interference in a commercial installation. 

This equipment generates, uses, and can radiate radio frequency energy and, if not 

installed or used in accordance with the instructions, may cause harmful interference 

to radio communications. However there is no guarantee that interference will not occur in a particular installation. If 

this equipment does cause harmful interference to radio or television reception, which can be determined by turning 

the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following 

measures: 1) reorient or relocate the receiving antenna; 2) increase the separation between the equipment and the 

receiver; 3) connect the equipment to an outlet on a circuit different from that to which the receiver is connected; 

4) consult the dealer or an experienced radio/TV technician for help. Any changes or modifications not expressly 

approved by the party responsible for compliance could void the user’s authority to operate the equipment. Where 

shielded interface cables have been provided with the product or specified additional components or accessories 

elsewhere defined to be used with the installation of the product, they must be used in order to ensure compliance 

with FCC regulations.

1.  Read these instructions.

2.  Keep these instructions.

3.  Heed all warnings.

4.  Follow all instructions.

5.  Do not use this product near water.

6. 

Clean only with a dry cloth.

7. 

Do not block any ventilation openings. Install in 

accordance with the manufacturer’s instructions.

8.  Do not install or place this product near any heat 

sources such as radiators, heat registers, stoves, or 

other apparatus (including amplifiers) that produce 

heat.

9.  Do not defeat the safety purpose of a polarized 

or grounding-type plug. A polarized plug has two 

blades with one wider than the other. A grounding 

type plug has two blades and a third grounding 

prong. The wide blade or the third prong are 

provided for your safety. If the provided plug does 

not fit into your outlet, consult an electrician for 

replacement of the obsolete outlet.

10. 

Protect the power cord from being walked on 

or pinched particularly at plugs, convenience 

receptacles, and the point where they exit from the 

product.

11. 

Only use attachments/accessories specified by 

Atlona.

12.  To reduce the risk of electric shock and/or damage 

to this product, never handle or touch this unit or 

power cord if your hands are wet or damp. Do not 

expose this product to rain or moisture.

13.  Unplug this product during lightning storms or when 

unused for long periods of time.

14. 

Refer all servicing to qualified service personnel. 

Servicing is required when the product has been 

damaged in any way, such as power-supply cord or 

plug is damaged, liquid has been spilled or objects 

have fallen into the product, the product has been 

exposed to rain or moisture, does not operate 

normally, or has been dropped.

CAUTION: TO REDUCT THE RISK OF

ELECTRIC SHOCK

DO NOT OPEN ENCLOSURE OR EXPOSE

TO RAIN OR MOISTURE.

NO USER-SERVICEABLE PARTS

INSIDE REFER SERVICING TO

QUALIFIED SERVICE PERSONNEL.

CAUTION

RISK OF ELECTRIC SHOCK

DO NOT OPEN

The exclamation point within an equilateral triangle is intended to alert the user to 

the presence of important operating and maintenance instructions in the literature 

accompanying the product.

The information bubble is intended to alert the user to helpful or optional opera-

tional instructions in the literature accompanying the product.

Important Safety Information

Содержание AT-GAIN-120

Страница 1: ...AtlonaManuals Audio AT GAIN 120 Audio Power Amplifier Stereo Mono 120 Watts...

Страница 2: ...AT GAIN 120 2 Version Release Date Notes 1 4 18 Initial release Version Information...

Страница 3: ...oluntary and failure to register will not affect the product warranty To register your product go to http www atlona com registration Sales Marketing and Customer Support Welcome to Atlona Operating N...

Страница 4: ...uct Warranty Terms New Products 10 years from proof of purchase date for hardware electronics products purchased on or after June 1 2013 3 years from proof of purchase date for hardware electronics pr...

Страница 5: ...s or states do not allow the exclusion or limitation of relief special incidental consequential or indirect damages or the limitation of liability to specified amounts so the above limitations or excl...

Страница 6: ...ole de la fl che du triangle quilat ral est destin alerter l utilisateur de la pr sence d une tension dangereuse non isol e dans l enceinte du produit qui peut tre suffisamment importante pour constit...

Страница 7: ...Do not use this product near water 6 Clean only with a dry cloth 7 Do not block any ventilation openings Install in accordance with the manufacturer s instructions 8 Do not install or place this prod...

Страница 8: ...icators 19 Power Modes 20 Powering On or Off 20 Auto Power Down mode 20 Hibernation mode 21 Network Audio 22 Dante Software Configuration 22 Enabling AES67 Support 23 Volume Control 25 Factory Reset 2...

Страница 9: ...face AT GAIN NET receives two channel audio from OmniStream AV encoders or compatible audio devices Optional AT RACK 1RU rack shelf highly recommended for rack installation Automatic standby after 25...

Страница 10: ...more information 6 ANALOG IN Connect an audio source to this port using the included 5 pin captive screw connector Refer to Audio Connectors page 11 for wiring information 7 RESET Press and hold this...

Страница 11: ...port When connecting program stereo speakers set the MODE switch to either 4 or 8 depending upon the speakers impedance Audio Connectors ANALOG IN LINE OUT 4 8 OUT GND Side View Side View GND 2 1 3 2...

Страница 12: ...Remove at least 3 16 5 mm from the insulation of each wire 3 Connect the wires as shown Voltage level Function Voltage is 0 or less than 3 V Off Voltage is 3 V or greater 30 V max On Connect a distri...

Страница 13: ...8 This mode is used for consumer applications and shorter speaker cable runs Connection Instructions Installation Program stereo speakers low impedance Distributed speakers high impedance 4 Connect th...

Страница 14: ...yer AT GAIN 120 Distributed Speakers Audio Ge ne ric SPEA KER SYST EMS SPEA KER SYST EMS Ge ne ric SPEA KER SYST EMS SPEA KER SYST EMS Ge ne ric SPEA KER SYST EMS SPEA KER SYST EMS Ge ne ric SPEA KER...

Страница 15: ...then the unit will be assigned the following IP configuration IP address 192 168 1 254 Subnet mask 255 255 0 0 Gateway 192 168 1 1 If a static IP address is desired the unit can be switched to static...

Страница 16: ...requires three arguments the desired IP address of the AT GAIN 120 the subnet mask and the gateway address All arguments must be entered in dot decimal notation The following is an example IPStatic 1...

Страница 17: ...sired web browser and enter the IP address of the AT GAIN 120 2 Log in using the required credentials The factory default username and password are listed below Username admin Password Atlona 3 Click...

Страница 18: ...AT GAIN 120 18 Basic Operation 5 The following message box will be displayed 6 Click OK to accept the changes or click Cancel to abort changes and return to the Network page...

Страница 19: ...s live Firmware update is in progress Refer to Updating the Firmware page 34 for more information SIGNAL Solid green An active signal is present on the selected input DEVICE ID Off Flashing green Unit...

Страница 20: ...ired web browser and enter the IP address of the AT GAIN 120 2 Log in using the required credentials The factory default username and password are listed below Username admin Password Atlona 3 Click t...

Страница 21: ...ing methods Press and hold the IP RESET button on the rear panel for approximately 3 seconds but no longer that 5 sec onds using the end of a paper clip or other pointed object Pull the trigger high u...

Страница 22: ...e Controller software from the following URL https www audinate com products software dante controller 2 Make sure that an Ethernet cable is connected from the INPUT port on the rear panel to the netw...

Страница 23: ...NET audio card has a maximum of two channels of audio Refer to the Dante Controller User Guide for details on operation 1 Double click the network card under Dante Receivers Enabling AES67 Support In...

Страница 24: ...the New drop down list and select Enabled 4 A message box will be displayed prompting to confirm AES67 is to be enabled Click Yes 5 Another message box will be displayed In order for AES67 to be enabl...

Страница 25: ...22 2 4 20 19 14 9 22 2 4 20 19 14 9 dB ANALOG IN L 4 8 OUT 70V 100V OUT AT GAIN 120 PWR 100 120VAC 60Hz 120W 220 240VAC 50Hz 120W L R L R IP 4 8 100V 70V R INPUT GAIN L R RESET button Output audio le...

Страница 26: ...efer to IP Configuration page 15 The default static IP address of the AT GAIN 120 is 192 168 1 254 Introduction to the Web GUI 1 Launch a web browser 2 In the address bar type the IP address of the AT...

Страница 27: ...ged out the AT GAIN 120 will display the login screen Menu Bar The window on the left side of the screen is the menu bar The menu system is divided into three sections Home Settings and Configuration...

Страница 28: ...ick this button to save the system settings to a local file System settings files are saved in bin binary format The default system settings filename is systemsettings bin It is recommended to save th...

Страница 29: ...rmware update procedure Browse Click this button to select the firmware file Click the Load button to begin the update procedure Refer to Updating the Firmware page 34 for more information Load Click...

Страница 30: ...80 This field cannot be modified IP Timeout Enter the time out interval in seconds in this field This field represents the time interval before the TCP IP connection times out Hostname Enter the desi...

Страница 31: ...own mode Refer to Auto Power Down mode page 20 for more information Hibernation Enables or disables hibernation mode Refer to Hibernation mode page 21 for more information Unit Trigger Enables or disa...

Страница 32: ...eld Special characters e g etc are not permitted Save Cancel Click the Save button to apply all changes Click the Cancel button to abort changes Change Admin Password Old password Enter the current pa...

Страница 33: ...all equalizer bands to their default settings Refer to Default Settings page 41 for more information Mute Click this button to mute the audio output Note that clicking this button will mute all audio...

Страница 34: ...nected between the AT GAIN 120 and the network The computer used to access the web GUI must be on the same network as the AT GAIN 120 2 Type the IP address of the AT GAIN 120 into the web browser as s...

Страница 35: ...d uses the default name of systemsettings bin 7 Click Firmware on the left side of the screen 8 Click the Browse button to select the firmware file 9 Click the Load button to begin the upgrade process...

Страница 36: ...and drop the firmware file on the computer to this folder Wait for the file to be copied 7 Disconnect both the USB cable and power cable from the AT GAIN 120 8 Reconnect the power to the AT GAIN 120 T...

Страница 37: ...VO L LEVE L AU DIO AM PLIFIER FW SIG NA L AN AL OG IN NE T AU DIO DE VIC E ID GA INTM LA N IN PU T NE TW OR K AU DI O RE SE T RE SE T LIN E OU T CL AS S 2 W IRI NG CL AS S 2 W IRI NG TR IG GE R MO DE...

Страница 38: ...place After the faceplate is removed set it aside Keep the two screws to attach the included faceplate with the INPUT card WARNING To prevent the risk of electrocution or electric shock always discon...

Страница 39: ...uide and gently push the AT GAIN NET network card forward until it locks in place The card will make a small snapping sound once the card is in place Lower Rail Upper Rail Plastic Guides IMPORTANT Whe...

Страница 40: ...ghten the screws using high torque devices as this may cause damage to the screws or the faceplate assembly 7 Card installation is complete 8 Connect the power cable to the AT GAIN 120 9 Connect an Et...

Страница 41: ...e digits of serial number OFF Control Power Auto Power Down Auto Power Down Timer min Hibernation Unit Trigger Blink OFF Enabled 15 Disabled Disabled Disabled Users Admin username Admin password admin...

Страница 42: ...ator green DEVICE ID 1 LED indicator green ANALOG IN 1 LED indicator green NET AUDIO 1 LED indicator green VOL LEVEL 1 Multi LED indicator Input Signal Analog Input Balanced 20 k unblanced 10 k CMRR 5...

Страница 43: ...to 70 C Humidity RH 90 RH non condensing Power Standby Mode Powers down after 5 25 minutes adjustable of no signal complies with ENERGY STAR power consumption limits of 0 5 W in standby mode Consumpti...

Страница 44: ...34 updating using USB 36 H Hibernation mode See Power modes hibernation mode I Installation 11 IP configuration using commands 16 using rear panel 15 using the web GUI 17 L LED indicators 19 M Mode s...

Страница 45: ...AT GAIN 120 45 Index V Volume adjusting 25 33 W Warranty 4 Web GUI 26...

Страница 46: ...registered trademarks of Atlona Inc All other brand names and trademarks or registered trademarks are the property of their respective owners Pricing specifications and availability subject to change...

Отзывы: