Installation
35
PVL14OF-EXT
7.16.3 Accessories Installation
• Install the ramps on the rear runways
using the ramp pin and two split pins
5X45 as shown in fi g.31.
• Check and install all pulley covers on the
corners of the beams.
• Remove the space bar from the runways.
7.17 Check Before Start-Up
During START UP procedure, observe all operating components
and check for proper installation and adjustment. DO NOT
attempt to raise vehicle until a thorough operation check has
been completed.
7.17.1 General Checks
• Make sure to check that the columns are plumb;
• Make sure to check the lift anchored to the ground and all anchor bolts
tightened.
• Make sure to check the electrical system feeding voltage is equal to that
specifi ed in the nameplate on the motor;
• Make sure to check the electric system connection in conformity of
the electric plan shown as the electric diagram (fi g. 6) and for proper
grounding.
• Make sure to check all plastic sliders are on the position and greased
properly.
• Make sure to check all pins are installed correctly and greased properly.
• Make sure to check all bolts, nuts and screws are tightened securely.
• Particularly, below checks must be followed: