Limited Warranty

All products manufactured by AtlasIED are warranted to the original dealer/installer, industrial or commercial purchaser to be free from defects in 
material and workmanship and to be in compliance with our published specifications, if any. This warranty shall extend from the date of purchase for 
a period of three years on all AtlasIED products, including SOUNDOLIER brand, and ATLAS SOUND brand products except as follows: one year on 
electronics and control systems; one year on replacement parts; and one year on Musician Series stands and related accessories. Additionally, fuses 
and lamps carry no warranty. AtlasIED will solely at its discretion, replace at no charge or repair free of charge defective parts or products when the 
product has been applied and used in accordance with our published operation and installation instructions. We will not be responsible for defects 
caused by improper storage, misuse (including failure to provide reasonable and necessary maintenance), accident, abnormal atmospheres, water 
immersion, lightning discharge, or malfunctions when products have been modified or operated in excess of rated power, altered, serviced or installed 
in other than a workman like manner. The original sales invoice should be retained as evidence of purchase under the terms of this warranty. All 
warranty returns must comply with our returns policy set forth below. When products returned to AtlasIED do not qualify for repair or replacement 
under our warranty, repairs may be performed at prevailing costs for material and labor unless there is included with the returned product(s) a written 
request for an estimate of repair costs before any nonwarranty work is performed. In the event of replacement or upon completion of repairs, return 
shipment will be made with the transportation charges collect.

EXCEPT TO THE EXTENT THAT APPLICABLE LAW PREVENTS THE LIMITATION OF CONSEQUENTIAL DAMAGES FOR PERSONAL INJURY, ATLASIED 
SHALL NOT BE LIABLE IN TORT OR CONTRACT FOR ANY DIRECT, CONSEQUENTIAL OR INCIDENTAL LOSS OR DAMAGE ARISING OUT OF THE 
INSTALLATION, USE OR INABILITY TO USE THE PRODUCTS. THE ABOVE WARRANTY IS IN LIEU OF ALL OTHER WARRANTIES INCLUDING BUT 
NOT LIMITED TO WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE.

AtlasIED does not assume, or does it authorize any other person to assume or extend on its behalf, any other warranty, obligation, or liability. This 
warranty gives you specific legal rights and you may have other rights which vary from state to state.

Service

Should your ASP-MG24 / ASP-MG24TDB require service, please contact the AtlasIED warranty department at

1-800-876-3333 or [email protected] to obtain an RA number.

AtlasIED Tech Support can be reached at 1-800-876-3333 or www.atlasied.com/support.

Visit our website at www.atlasied.com to see other AtlasIED products.

Содержание ASP-MG24

Страница 1: ...1 AtlasIED com TELEPHONE 800 876 3333 SUPPORT ATLASIED COM 1601 JACK MCKAY BLVD ENNIS TEXAS 75119 U S A ASP MG24 ASP MG24TDB Signal Processor Masking Generator 2 Input x 4 Output...

Страница 2: ...TEXAS 75119 U S A Table of Contents Important Safety Instructions 3 Introduction 5 Key Features 5 Front Panel Description 6 Rear Panel Description 7 Getting to Know the Software 8 Mic Line Input 9 Ma...

Страница 3: ...our electrician to replace your obsolete outlet Do not defeat the safety purpose of the grounding type plug 14 Unplug this device during lightning storms or when unused for long periods of time 15 Ref...

Страница 4: ...connecting equipment Fire and or property damage may result Operate the product only with the voltage specified on the unit Fire and or electric shock may result if a higher voltage is used Do not mod...

Страница 5: ...ections 31 band EQ white pink noise auto ramp routing mixing and compressor limiters The ASP MG24 can be controlled or configured in real time with the intuitive PC GUI accessed via the RS 232 or USB...

Страница 6: ...2 Level LED Indicators 5 LEDs per channel indicate the status of the signal level Signal 12dB 6dB 3dB Over Limit A dual use LED indicates maximum headroom and limiter threshold 3 RS232 Connector Stand...

Страница 7: ...lying signal to the input set the analog gain switch to match the type of input being used The Line position gain is calibrated for 0dBu or unity gain within the DSP software The Mic position gain is...

Страница 8: ...rsonal viewing preferences 3 After the software is loaded and the proper screen resolution is set open the software and follow the steps below Note It is not necessary to have the computer connected t...

Страница 9: ...d is PRE input filters and compressor settings Gain For convenience both Mic Line inputs and the four masking generators levels are shown Controlling the gain can be accomplished by dragging the fader...

Страница 10: ...second is the settings screen This screen controls Threshold Attack Release and Ratio Adjustment can be made using the up down arrows or by typing into the data viewing text box Threshold Limit thresh...

Страница 11: ...tion Also use the screen curser up down arrows to find the three screens All 3 screens can be moved by clicking and holding the selected screen for personal viewing preferences Graphic Screen This scr...

Страница 12: ...AS 75119 U S A Crossover Window The Crossover window allows the adjustment of filter type frequency and slope The Reset button will set all filters back to factory settings and only affects the settin...

Страница 13: ...red turn on signal ramp time during power up The Time buttons allow adjustment of the amount of preset time needed The amount of steps is a formula of gain divided by time The ramp interval voltage ch...

Страница 14: ...l Mute can be accomplished by clicking on the Mute button It will illuminate red indicating the channel is in Mute Masking EQ When clicking on the filter screen 3 sub viewing screens appear Note All 3...

Страница 15: ...settings and only effects the settings in this screen There are 20 1 3 octave band filters available to adjust the measured masking signal A generous 15dB and 30dB boost and cut are offered in 0 25dB...

Страница 16: ...to 0dB Controlling the mixed gain can be accomplished by dragging the fader using the up down buttons or typing in the number viewing text box Note The signal feeding into the mixer will not be effect...

Страница 17: ...screens can be moved for personal viewing preferences Graphic Screen This screen will display all of the filter characteristics that are set Filter Window Each input has 8 adjustable filter selection...

Страница 18: ...Delay Window The Delay window allows adjustment of the channel delay from 0ms to 200ms per output Controlling the mixed gain can be accomplished by using the up down buttons or by typing in number vi...

Страница 19: ...ndicator screen showing the compressor limiter operation Screen 2 is the settings screen which controls Threshold Attack Release and Ratio Adjustment can be made using the up down arrows Threshold Lim...

Страница 20: ...BLVD ENNIS TEXAS 75119 U S A Mute Channel Mute can be accomplished by clicking on the Mute tab and will illuminate red indicating the channel is in Mute Output Meter The bar graph meter illustrates t...

Страница 21: ...and Export Master Reset All This button is the master reset button and will override all settings Note A confirmation widow will pop up File Open Program files can be recalled from the PC or Laptop It...

Страница 22: ...in non volatile memory that can store up 14 different program setups A program can be recalled from the device When doing so only one program can be open on the desktop GUI Once recalled the program...

Страница 23: ...rs and sound masking setups Meter Real time meters for all inputs outputs Scaled in V RMS dBu and dBV These are helpful when troubleshooting Scheduler The ASP MG24TDB contains a programmable clock and...

Страница 24: ...ck the Initial Ramp Commission button 2 Click the Start Date drop down menu and select the start date 3 Set the start level for the masking signal typically 10dB down from the target level 4 Click the...

Страница 25: ...allow selection of any of the 4 masking channels and 2 inputs to be configured to a schedule as well as choosing the day of the week to program To reduce data entry time create a schedule for one day...

Страница 26: ...uts 4 Outputs 3 pin Balanced Phoenix DC Power Receptacle 5 Pin DIN Connector Audio Control Parameters Gain 40dB to 15dB in 0 25dB Steps Polarity Delay Up to 200ms per I O Parametric Filters 8 per I O...

Страница 27: ...ters High Performance 24 bit Propagation Delay 3ms Electrical Specifications General Input Impedance Line 10k Ohms Mic Output Impedance 50 Ohms Maximum Input Output Level 20dBu Frequency Response 20Hz...

Страница 28: ...T ATLASIED COM 1601 JACK MCKAY BLVD ENNIS TEXAS 75119 U S A Dimensional Drawings Power Data ASP MG24 2x4 Signal Processor Masking Generator 1 2 Over Limit 3dB 6dB 12dB Signal Inputs RS232 USB 1 2 3 Ou...

Страница 29: ...29 ASP MG24 Owner s Manual AtlasIED com TELEPHONE 800 876 3333 SUPPORT ATLASIED COM 1601 JACK MCKAY BLVD ENNIS TEXAS 75119 U S A Notes...

Страница 30: ...30 ASP MG24 Owner s Manual AtlasIED com TELEPHONE 800 876 3333 SUPPORT ATLASIED COM 1601 JACK MCKAY BLVD ENNIS TEXAS 75119 U S A Notes...

Страница 31: ...31 ASP MG24 Owner s Manual AtlasIED com TELEPHONE 800 876 3333 SUPPORT ATLASIED COM 1601 JACK MCKAY BLVD ENNIS TEXAS 75119 U S A Notes...

Страница 32: ...ed or operated in excess of rated power altered serviced or installed in other than a workman like manner The original sales invoice should be retained as evidence of purchase under the terms of this...