– 19 –
ASP-MG24
Owner’s Manual
AtlasIED.com
TELEPHONE: (800) 876-3333
1601 JACK MCKAY BLVD.
ENNIS, TEXAS 75119 U.S.A.
Limiter
All 4 outputs have fully adjustable hard limiters. When clicking on the limiter tab, 2 sub viewing screens will appear.
Note:
All control boxes can be
dragged for desired positioning of the screen. Screen 1 is an indicator screen showing the compressor / limiter operation. Screen 2 is the settings
screen which controls Threshold, Attack, Release and Ratio. Adjustment can be made using the up / down arrows.
• Threshold - Limit Threshold. Ranges from -20 to +20dBu in 0.5dB steps.
• Attack - Attack time. Ranges from 0.3 to 1ms in 0.1ms steps, and ranges from 1 to 100ms in 1ms steps.
• Release - Release time. Can be set at 2X, 4X, 8X, 16X or 32X the attack time.
• Ratio - The Ratio control allows adjustment to the amount of Input vs. Output level with signals exceeding the set threshold limit.