1. High voltage and moving parts around motors and motor driven equipment can cause serious
or fatal injuries. Always disconnect power source at main switch before wiring, servicing or
cleaning unit. Do not rely on fan control device to prevent unexpected start-up or electrical
shock. In addition, power supply must have fuses or circuit breakers for short circuit protection.
2. All electrical wiring must be performed by qualified persons in accordance and conform with
the AS/NZS 3000 wiring rules.
3. Fan should be secure in its electrical grounding to avoid possible electrical shock.
4. Fan should not be used in any wet or hazardous location defined by article 500 of the NEC.
In addition, its ambient temperature should not exceed 40 degrees Celsius.
5. Power supply should conform to voltage rating of 220-240V~, 50/60Hz.
6. Before applying power, visually re-inspect the installation. Make sure that all guards and
protective devices are securely in place and all visible screws and bolts are tightened.
7.
Warning:
to reduce the risk of fire, electrical shock or personal injury, mount hanging bracket
to a structure capable of supporting a hanging weight of 21 Kgs. Do not mount fan to sheet
rock or plasterboard type material.
8.
Caution:
to reduce the risk of injury to persons, install fan so that bottom edges of fan blades
are to be at least 2.3m above the floor.
9. To reduce the risk of personal injury, do not bend blades or any other part of fan when
cleaning. Do not insert foreign objects in between rotating fan blades or in space
surrounding entire rotating fan unit. Fan must be turned off at power at supply source before
installation, cleaning or servicing.
10. Instructions for Supply Connections: Conductor of a fan identified as grounded conductor to
be connected to a grounded conductor of a power supply, conductor of fan identified as
ungrounded conductor to be connected to an ungrounded conductor of a power supply,
conductor of fan identified for equipment grounding to be connected to an equipment-
grounding conductor. Be sure that all wiring connections are properly insulated from each
other and any surrounding metal parts. For safety and best operating results, only a
qualified electrican is allowed to assemble and install your fan.
11. To reduce the risk of personal injury, install the supplementary mounting means and use only the
hardware provided with the fan.
12. Warning:
TO REDUCE THE RISKS OF FIRE, ELECTRIC SHOCK OR INJURY TO PERSONS,
OBSERVE THE FOLLOWING:
A. Use this unit only in the manner intended by the manufacturer. If you have any questions,
contact the manufacturer.
B. Before installing, servicing or cleaning unit, switch power off at service panel and lock
service panel to prevent power from being switched on accidentally.
READ AND SAVE THESE SAFETY AND INSTALLATION
INSTRUCTIONS.
Consult a licensed electrician if unsure of any point below mentioned.
DANGER/WARNING/CAUTION