SmartROC D65 Tier 4 Final
14 Options
198
1.
Mount the tester on the multimeter. Make sure the pins are positioned correctly ac-
cording to the colour markings. Red pin to V/Ohm on the multimeter. Set the multi-
meter measuring range to ohms.
2.
Connect the tester's 5-pin connectors to the CAN network requiring measurement:
Decoder: contact X3 or X4.
Display, application and master modules: connector X2, X3 or X4.
I/O modules: contact X1 or X19.
Resolver modules: contact X3 or X4.
3.
Select CABLE TEST on the CAN tester. The multimeter should read about 60-65
Ohms if the cable is intact.
Fault indication
n
If the multimeter reads 120 Ohm, the end plug is missing or there is a break in a cable.
!
NOTE:
Because of the internal resistance in the tester, the multimeter reads about 100
kOhm if the cables are not connected or if there is an open circuit in one of the cables.
14.2.3 I/O module
Checking the digital inputs
There are two digital inputs designated A and B at each contact Normally, the signal is 0V
for an open contact and +24V for a closed contact.
Pin
Function
1
+24V DC
2
Signal B
3
GND
4
Signal A
5
GND
Table 21:
Pin configuration
Содержание SMARTROC D65 TIER 4 FINAL
Страница 2: ......
Страница 4: ......
Страница 10: ...SmartROC D65 Tier 4 Final Table of Contents x...
Страница 32: ...SmartROC D65 Tier 4 Final 2 General 32...
Страница 38: ...SmartROC D65 Tier 4 Final 3 Transport instructions 38...
Страница 50: ...SmartROC D65 Tier 4 Final 5 RCS drilling system 50 Rig Layout Feeder Layout...
Страница 69: ...SmartROC D65 Tier 4 Final 5 RCS drilling system 69 Rig Layout Feeder Layout...
Страница 86: ...SmartROC D65 Tier 4 Final 5 RCS drilling system 86 Logging Signal Log Signal Log...
Страница 109: ...SmartROC D65 Tier 4 Final 5 RCS drilling system 109 Drilling DCT DCT n Parameters n Actuations...
Страница 112: ...SmartROC D65 Tier 4 Final 5 RCS drilling system 112 5 9 Rig 5 9 1 Rig menu Rig menu n Sensors n Actuations n Parameters...
Страница 113: ...SmartROC D65 Tier 4 Final 5 RCS drilling system 113 Rig sensor Rig sensor n Power Pack n Wagon Frame...
Страница 120: ...SmartROC D65 Tier 4 Final 5 RCS drilling system 120 Rig parameters Parameters n Tramming...
Страница 140: ...SmartROC D65 Tier 4 Final 6 Hydraulic systems 140...
Страница 157: ...SmartROC D65 Tier 4 Final 9 Dust collector DCT 157 Dust collector...
Страница 158: ...SmartROC D65 Tier 4 Final 9 Dust collector DCT 158...
Страница 160: ...SmartROC D65 Tier 4 Final 10 Radiator 160 Radiator and expansion tank...
Страница 170: ...SmartROC D65 Tier 4 Final 11 Diesel engine 170...
Страница 182: ...SmartROC D65 Tier 4 Final 12 Compressor and air system 182...
Страница 192: ...SmartROC D65 Tier 4 Final 13 Oil and fuel 192...
Страница 219: ...14 Options 219...
Страница 220: ...www atlascopco com 2015 12 17 No 713991051 3...