NOTICE
A single USB stick can be used to download diagnostics from several PP100. A unique sub folder
with serial number will be created for each machine.
NOTICE
A USB stick can be used for consecutive diagnostic downloads without having to be erased in
between. All new error log information is appended to the existing error log file.
The diagnostic files can either be used for end user diagnostics or sent to an autorised workshop for review.
Diagnostic files
The file Deviceinfo.txt contains the following information:
Comment
Linte text
PP100 Serial number.
Serial number: <Serialnumber>
Total uptime (drill time + idle time + stand-by time).
Uptime: <Hours>
Total drill time.
Drilltime: <Hours>
Time to next service. Set to 300 hours.
Time to service: <Hours >
Control unit software version.
CU SW: <Version>
Power unit software version.
PU SW: <Version>
Driver unit serial number.
ASNR: <Serialnumber>
The information in this file can be used to determine how much time the machine is used, both actual running
time, but also idle and standby. The remaining information in the file concerns software versions in the different
control and power units. This information can be used by an authorised workshop to determine if a software
upgrade is needed.
NOTICE
Software upgrades can only be performed by an authorised workshop.
The error log file Errorlog.txt contains the following information:
Event
Line text
Timestamp for errorlog start.This row also contains the serial number
of the machine.
ERRORLOG_START <Timestamp>
Error with number <ErrorNumber> and with the name <Error name>
Time for the error. <Timestamp>.
<Timestamp> <Errornumber> <Errorname>
End of Errorlog.
ERRORLOG_DONE
The different error messages are explained in the table below:
Remedy
Description
Error text
Error log
no.
-
Low supply voltage, < 0.90 * Supply
voltage. Output power is reduced.
ERR_MINOR_LOW_VOLTAGE
0
Connect the hydraulic hoses.
Start without hydraulic hoses
connected.
ERR_START_WITHOUT_HYDRAULICS
3
Check and remedy the power
supply.
High supply voltage, >1,1 * Supply
voltage; PP100 to standby.
ERR_HIGH_VOLTAGE
4
Check and remedy the power
supply.
Low supply voltage, < 0.70 * Supply
voltage; PP100 to standby.
ERR_MAJOR_LOW_VOLTAGE
5
Check and remedy the power
supply.
Supply phase loss.
ERR_PHASE_LOSS
7
-
Power reduction.
ERR_WINDING_HIGH_TEMP_MEDIUM
35
-
Power reduction.
ERR _ROTOR_HIGH_TEMP_MEDIUM
36
-
Power reduction.
ERR _DRIVER_HIGH_TEMP_MEDIUM
37