Connect the power supply (A), see illustration
below.
B
A
♦
Check the hydraulic oil level, LED 3 (B).
♦
Inspect the LED indicators (B). Flashing or
continuous lighting LEDs indicate errors that need
to be adressed before start.
Start and stop
A
1. Switch on the main supply. The On/Off button
(A) on the top of the power pack is flashing (0,5
Hz), the machine is in stand-by mode.
2. Start the power pack by pressing the On/Off
button, the button lights up.
3. Stop the power pack by pressing the On/Off
button, the button is flashing (0,5 Hz). The
machine is in stand-by mode.
4. If the On/Off button, in stand-by mode, is flashing
fast (2 Hz) the machine must be serviced.
Power on demand
The power pack is equipped with a power on demand
function. When pressing the On/Off-button, the RD
100 is in idling mode with a low RPM. When pressing
the attached machine's throttle the engine is
increasing to work mode. Release the throttle and
the power pack returns to idling mode.
Emergency stop
In case of emergency during operation, press the
emergency stop (A). The power pack will stop and
the LED 1 (B) indicator lights continuously.
A
B
C
1. Check and correct the error before restarting the
power pack.
2. Reset the emergency stop (A) by turning the
emergency stop button.
3. Press the On/Off button (C) to get the power pack
in stand-by mode.
4. Start the power pack by pressing the On/Off
button (C).
NOTICE
Do not use the emergency stop to shut off
the power pack during normal operation.
Reinforced cooling and power
reduction
The cooling water outlet (A) is used during reinforced
cooling.
15
© 2016 Construction Tools PC AB | No. 9800 1364 01c | 2016-04-06
Original instructions
Safety and operating instructions