4
PAGE
Repair Instructions No.163.01/96
PHE 20 / PHE 26 / PHE 200
Lubrication
Each time maintenance is performed, the machine is to be lubricates as stated in the lubrication plan.
After the machine is fully disassembled, completely remove the old grease and replace with new
grease. The grease must be applied to the machine as indicated in the lubrication plan.
Legend
A
Cover with grease 10 g Tivela
B
Cover with grease 10 g Darina
C
Fill with grease Tivela
Torques
Gear box screws
3,0 Nm
(additionally secure with screw locking device)
Housing screws (plastic)
2,0 Nm
B
A
A
B
B
B
B
C
A
A
B
Содержание PHE 20