2920 1454 00
24
Instruction book
4.8 Service kits
Service kits are available offering you the benefits of genuine
Atlas Copco parts while keeping the maintenance budget low.
The kits comprise all parts needed for servicing.
See section 4.4.1 for the ordering number for Atlas Copco
Roto-injectfluid.
Footnotes chapter 4
1)
Use only authorized parts. Any damage or malfunction caused
by the use of unauthorized parts is not covered by Warranty or
Product Liability.
2)
Using key <<Rset>> in submenu <<Service>>: see User manual
for Elektronikon regulator, section "Service submenu".
5 ADJUSTMENTS AND SERVICING
PROCEDURES
5.1 Air filter
5.1.1 Recommendations
1. Never remove the element while the compressor is running.
2. For minimum compressor down-time, replace the dirty
element by a new one.
3. Discard the element when damaged.
5.1.2 Servicing
1. Stop the compressor. Switch off the voltage. Remove the
air filter cover by turning it anti-clockwise. Remove the
filter element. Clean the cover. Discard the filter element.
2. Install a new element and the cover.
3. Reset the service indicator (1-Fig. 3.3) by pushing the reset
knob.
4. Reset the air filter service warning
1)
.
5.2 Coolers
Keep the coolers clean to maintain the cooling efficiency.
To facilitate external cleaning of the coolers, the side panels
can be removed.
Remove any dirt from the coolers with a fibre brush. Never
use a wire brush or metal objects. Then clean by air jet in
reverse direction of normal flow.
Refit the side panels.
5.3
Safety valve
Operating
Operate the safety valve by unscrewing the cap one or two
turns and retightening it.
Testing
The valve can be tested on a separate compressed air line. If
the valve does not open at the pressure specified in section
7.2, consult Atlas Copco. No adjustments are allowed.
Footnote chapter 5
1)
Using key <<Rset>> in submenu <<Service>>: see User manual
for Elektronikon regulator, section "Service submenu".