![Atlas Copco GA18 VSD Скачать руководство пользователя страница 11](http://html.mh-extra.com/html/atlas-copco/ga18-vsd/ga18-vsd_instruction-book_3001676011.webp)
2920 1454 00
11
Instruction book
Compressor out
bar
7.0
rpm
5065
¯
Menu
F1
F2
F3
Fig. 1.8 Example of the main screen
Status data
®
Measured data
Counters
Main
¯
F1
F2
F3
Fig. 1.9 Example of a main menu
Figs. 1.8 and 1.9 Displays
Calling up other menus
Starting from the Main screen:
- Use the
¯
key (1-Fig. 1.7) for a quick look at the actual
compressor status
- Press the key Menu (F1), the option Status data will be
followed by a horizontal arrow:
- either press the tabulator key (2-Fig. 1.7) to select this
menu
- or use the
¯
key (1-Fig. 1.7) to scroll until the desired
submenu is followed by a horizontal arrow and then
press tabulator key to select this menu
1.4 Electric cabinet (Fig. 1.10)
The electric cabinet mainly comprises transformers, fuses, a
fan motor contactor and circuit breaker, and for Full-feature
compressors also the dryer contactor.
The Elektronikon regulator and emergency stop button are
fitted in the door of the cabinet.
The converter cabinet comprises the start and speed regulation
unit. The parameters of the start and speed regulation unit are
factory-set and need no adjustment. Changing the parameters
may damage the compressor; consult Atlas Copco.
F1
Circuit breaker
F4/F5/F6 Fuses
K11
Contactor, dryer
K15
Contactor, fan motor
Q15 Circuit breaker, fan
motor
T1 Transformer
T2 Transformer
Fig. 1.10 Electric cabinet (typical example)
F1/F2
Fuses
F9
Circuit breaker
K21
Line contactor
PE Earth terminal
U1 Frequency converter