![Atlas Copco GA 37 VSD Скачать руководство пользователя страница 121](http://html.mh-extra.com/html/atlas-copco/ga-37-vsd/ga-37-vsd_instruction-book_3001661121.webp)
9.6
Compressor data
Reference conditions
All data specified below apply under reference conditions, see section
GA 37 VSD
13 bar
175 psi
13 bar
175 psi
13 bar
175 psi
Frequency
Hz
50
60
50
60
50
60
Number of compression stages
1
1
1
Normal effective working pressure
bar(e)
7
9.5
12.5
Maximum effective working pressure, Workplace Full-
Feature
bar(e)
7.3
9.8
12.8
Maximum motor shaft speed
rpm
3066
2683
2224
Minimum motor shaft speed
rpm
780
780
1172
Temperature of air leaving the outlet valve (approx.),
Workplace Full-Feature
˚C
23
23
23
Nominal motor power
kW
37
37
37
Dryer power at full load, Workplace Full-Feature units
kW
50 Hz
60 Hz
.
1.34
1.62
.
1.34
1.62
.
1.34
1.62
Refrigerant type, Workplace Full-Feature
R410A
R410A
R410A
Refrigerant quantity, Workplace Full-Feature
kg
50 Hz
60 Hz
.
0.97
1.01
.
0.97
1.01
.
0.97
1.01
Oil capacity, air-cooled
l
21
21
21
Sound pressure level, 60 Hz (according to ISO 2151
(2004))
dB(A)
67
67
67
9.7
Technical data controller
General
Supply voltage
24 V AC /16 VA 50/60Hz (+40%/-30%)
24 V DC/0.7 A
Type of protection
IP54 (front)
IP21 (back)
Ambient and temperature
conditions
IEC60068-2
Instruction book
API480496
119