Fault
code
Fault
description
Cause
Actions
0x6111
Drive failure
(software)
Internal CAN state machine fault
Check CAN-cable connection
between Elektronikon and converter.
Check position of the CAN
termination switch at both sides of the
CAN cable. Both should be OFF.
0x6112
Drive failure
(software)
Requested command cannot be
executed because of limited access
level
Try to reset the error.
If error returns, contact Atlas Copco.
0x6113
Drive failure
(software)
CAN communication overload
Check CAN-cable connection
between Elektronikon and converter.
Check position of the CAN
termination switch at both sides of the
CAN cable. Both should be OFF.
0x6114
Drive failure
(software)
The firmware version is not compatible
with the parameter version
Try to reset the error.
If error returns, contact Atlas Copco.
0x7130
Motor
overtemperature
Motor overtemperature detected
Let motor cool off. Ensure main fan
and air flow in and out compressor is
not obstructed. Ensure proper flow of
cool air in compressor room.
Check for loose connectors at the
control unit of the converter.
0x8401
Overvoltage
Motor maximum speed exceeded
Try to reset the error.
If error returns, contact Atlas Copco.
0x8402
Overvoltage
Motor startup unsuccessful; requested
speed not reached
Wait until the vessel depressurizes by
blow off. (by not resetting the fault
immediately).
If the problem persists, contact Atlas
Copco.
0x9001
Hardware run
enable missing
Hardware enable signal missing
Check for loose connectors at the
control unit of the converter and
Elektronikon.
Check for tripped fuses at the
secondary of the transformer T1 in
the electrical panel.
0x9065
to 91F4
Drive failure
(software)
Failure on attempt to write parameter
Pyyy out of range
Try to reset the error.
If error returns, contact Atlas Copco.
Control Technics (Optional)
Fault
code
Text on
converter
display
Cause
Actions
1
UU
Too low voltage. The voltage on the
converter is below the specifications.
Check the supply voltage.
Contact Atlas Copco.
2
OU
Too high voltage. The voltage on the
converter is above the specifications.
Check the supply voltage.
Contact Atlas Copco.
3
OI.AC
Too high current. The converter is
overloaded.
Contact Atlas Copco.
Instruction book
API480496
113