Check the display (2) regularly for readings and messages. The display normally shows the compressor
outlet pressure, while the status of the compressor is indicated by pictographs. Remedy the trouble if alarm
LED (7) is lit or flashes, see section
,
and Problem solving. The display (2)
will show a service message if a service plan interval has been exceeded or if a service level for a
monitored component has been exceeded. Carry out the service actions of the indicated plans or replace the
component and reset the relevant timer, see section
Compressors with Elektronikon® Graphic controller:
Control panel Elektronikon® Graphic
Check the display (2) regularly for readings and messages. The display normally shows the compressor
outlet pressure, while the status of the compressor is indicated by means of a number of icons. Remedy the
trouble if alarm LED (7) is lit or flashes, see section
. The display (2) will show a service
message if a service plan interval has been exceeded or if a service level for a monitored component has
been exceeded. Carry out the service actions of the indicated plans or replace the component and reset the
relevant timer, see section
.
7.6
Stopping
Control panel Elektronikon®
Instruction book
148
2920 7180 30
Содержание GA 30+
Страница 1: ...Atlas Copco Oil injected rotary screw compressors GA 30 GA 37 GA 45 Instruction book ...
Страница 2: ......
Страница 15: ...Motor side view GA 30 up to GA 45 Pack Instruction book 2920 7180 30 13 ...
Страница 16: ...Service side view GA 30 up to GA 45 Pack Instruction book 14 2920 7180 30 ...
Страница 17: ...Motor side view GA 30 up to GA 45 Full Feature Instruction book 2920 7180 30 15 ...
Страница 50: ...3 19 Calling up modifying pressure band settings Calling up the settings Instruction book 48 2920 7180 30 ...
Страница 139: ...6 4 Pictographs Description Pictographs 1 2 3 4 5 6 7 8 9 10 11 12 Instruction book 2920 7180 30 137 ...
Страница 188: ......
Страница 189: ......