Condition
Fault
Remedy
Too high temperature in oil
separator vessel or temperature
switch (TSHH1) defective
Find cause and remedy. Replace
if necessary.
Phase sequence relay (K25) open
Find cause and remedy. Replace
if necessary.
Wiring interrupted
Find cause and remedy. Replace
if necessary.
Compressor starts running, but
does not load after a delay time
Solenoid valve out of order
Replace valve
Inlet valve stuck in closed position
Have valve checked
Leak in control air tubes
Replace leaking tubes
Minimum pressure valve leaking
(when air net is depressurised)
Have valve checked
Compressor does not unload,
safety valve blows
Solenoid valve out of order
Replace valve
Inlet valve does not close
Have valve checked
Condensate is not discharged
from condensate separator during
loading
Discharge tube clogged
Check and correct as necessary
Compressor air output or pressure
below normal
Air consumption exceeds air
delivery of compressor
Check the connected equipment.
Choked air filter element
Replace filter element
Solenoid valve malfunctioning
Replace valve
Leak in control air tubes
Replace leaking tubes
Oil separator element clogged
Have element replaced
Air leakage
Have leaks repaired.
Safety valve leaking
Replace valve
Inlet valve does not fully open
Have valve checked
Compressor element out of order
Consult your supplier
Excessive oil consumption; oil
carry-over through discharge line
Incorrect oil causing foam
Change to correct oil
Oil level too high
Check for overfilling. Release
pressure and drain oil to correct
level.
Oil separator defective
Replace oil separator element
Safety valve blows after loading
Inlet valve malfunctioning
Have valve checked
Instruction book
2920 7180 30
163
Содержание GA 30+
Страница 1: ...Atlas Copco Oil injected rotary screw compressors GA 30 GA 37 GA 45 Instruction book ...
Страница 2: ......
Страница 15: ...Motor side view GA 30 up to GA 45 Pack Instruction book 2920 7180 30 13 ...
Страница 16: ...Service side view GA 30 up to GA 45 Pack Instruction book 14 2920 7180 30 ...
Страница 17: ...Motor side view GA 30 up to GA 45 Full Feature Instruction book 2920 7180 30 15 ...
Страница 50: ...3 19 Calling up modifying pressure band settings Calling up the settings Instruction book 48 2920 7180 30 ...
Страница 139: ...6 4 Pictographs Description Pictographs 1 2 3 4 5 6 7 8 9 10 11 12 Instruction book 2920 7180 30 137 ...
Страница 188: ......
Страница 189: ......