![Atlas Copco GA 11 VSD+ Скачать руководство пользователя страница 85](http://html.mh-extra.com/html/atlas-copco/ga-11-vsd/ga-11-vsd_instruction-book_3001655085.webp)
Energy recovery unit (ER-unit)
Main components of the ER unit (typical installation)
Reference
Designation
1
Water inlet pipe
2
Water outlet pipe
3
Temperature sensor, water inlet pipe
4
Temperature sensor, water outlet pipe
5
Oil drain valve
6
Oil line from compressor oil separator vessel to ER unit
7
Oil line from ER unit to oil filter housing
BV2
Location of heat exchanger by-pass valve (BV2)
HE
Heat exchanger
V1
Selector valve
AR
Oil separator vessel
OF
Oil filter housing
BV1
Location of oil cooler bypass valve (BV1)
Instruction book
2920 7109 23