Minimum
setting
Factory
setting
Maximum
setting
Proportional band
%
6
10
15
Integration time
sec
5
6
10
Parameters
Minimum
setting
Factory
setting
Maximum
setting
Minimum stop time
sec
5
5
30
Power recovery time
sec
10
10
3600
Restart delay
sec
0
0
1200
Communication time-out
sec
10
30
60
Fan motor starts per day (air-cooled
compressors)
1
240
240
Protections
Minimum
setting
Factory
setting
Maximum
setting
Compressor element outlet temperature
(shut-down warning level)
˚C
50
110
119
Compressor element outlet temperature
(shut-down warning level)
˚F
122
230
246
Compressor element outlet temperature
(shut-down level)
˚C
111
120
120
Compressor element outlet temperature
(shut-down level)
˚F
232
248
248
Specific protections for Full-Feature compressors:
Minimum
setting
Factory
setting
Maximum
setting
Dewpoint warning temperature
ºC
10
25
99
Dewpoint warning temperature
ºF
10
77
210
Service plan
The built-in service timers will give a Service warning message after their respective preprogrammed time
interval has elapsed.
For specific data, see section Preventive Maintenance.
Consult Atlas Copco if a timer setting needs to be changed. The intervals must not exceed the nominal
intervals and must coincide logically. See section
.
Instruction book
2920 7109 23
71
Содержание GA 11 VSD+
Страница 1: ...Atlas Copco Oil injected rotary screw compressors GA 7 VSD GA 11 VSD GA 15 VSD Instruction book ...
Страница 2: ......
Страница 16: ...2 2 Flow diagram GA 7 VSD up to GA 15 VSD Workplace Instruction book 14 2920 7109 23 ...
Страница 88: ...Flow diagram of compressor with energy recovery system Instruction book 86 2920 7109 23 ...
Страница 136: ......
Страница 137: ......