Troubleshooting
Problem
Cause
Solution
The power tool does not start.
The plug is not connected.
Connect the electrical plug into a power
socket.
Start switch is in off position.
Turn the switch on.
The carbon brushes are worn out.
Change the carbon brushes.
No power in the power socket.
Replace or repair the power socket.
Defective power switch
Replace the power switch.
The power tool switch trips out.
The internal vibrator is overloaded (when
operating in concrete or rebar).
Raise the the vibrator poker from the
concrete and immerse it again.
Air inlet or outlet is clogged and the power
Remove anything that may obstruct the air
tool is not cooled.
The electric motor fan is broken and the
power tool is not cooled.
Replace the fan at an authorised
workshop.
Nuts and bolts
fi
xating the outer casing has
Tighten the nuts and bolts. come loose.
Too much friction in the
fl
exible shaft.
Grease the
fl
exible shaft in the hose.
Too much grease on the
fl
exible shaft.
Respect the quantity of 15 grams per
meter of
fl
exible shaft.
Too much torque inside the the vibrating
poker (the bearings get worn out).
Replace the bearings in the vibrating
poker.
The
fl
exible shaft is overheating.
Too much friction in the
fl
exible shaft.
Grease the
fl
exible shaft in the hose.
The power tool vibrates too much.
The bearings of the power tool are worn
out.
Replace the bearings in the power tool at
an authorised workshop.
Too much friction in the
fl
exible shaft.
Grease the
fl
exible shaft in the hose.
The power tool is very noisy
The carbon brushes are worn out.
Change the carbon brushes.
The bearings are defective.
Replace the bearings.
The rotor is touching the stator.
Replace the rotor at an authorised
workshop.
The outer cladding is broken or has loose
Inspect the cladding and tighten the bolts.
bolts
The vibrating poker does not vibrate but
the power tool starts.
The bearings in the in the vibrating poker
are broken.
Replace the bearings in the in the
vibrating poker.
The
fl
exible shaft is broken.
Replace the