manualshive.com logo in svg
background image

Any revisions must first be approved by the product designer.  Version: 201911 

Revision By:  JST 

Detail in Fig. 1. 

Must be 

accurate. 

120mm from 

top of wall channel to 
top of end connector  
channel. 

 
 
 
 
 
 

10.

 

Apply plastic packers 
(bag11)into the base 
glazing channels in 
locations as shown.  
 

 

 

 

 

11.

 

CRITICAL SEAL 
Remove dust and dirt first. Seal the connection 
between the glass receiver channel and the base 
glazing channel 
with clear silicon 
prior to the 
installation of 
panel 

SL R. 

 
 
 
 

Ensure the corner junction between wall channel 
and base channel is full of silicon before final glass                            

placement. It is vital 
that all junctions are 
sealed sufficiently. 
                            
Prior to installation of 
glass panels and infill all 
connections 
of channels, must be 
sealed with clear silicon 
supplied

 

 

 

12.

 

Locate the glass panel 

SL R 

into the glazing 

channel. The top 
of panel 

SL R 

must be level with 
the top of the 
glass receiver 
channel on the 
door side. Adjust 
height of panel if 
necessary by 
adding or 
removing plastic 
packers (bag11) in 
the base glazing 
channels.  
 

13.

 

TOP RAIL BRACE INSTALLATION 
It is recommended 
that the top rail 
brace is fitted prior 
to tiling. AVOID 
SCRATCHING.

 

Trim to length if 
necessary. Slide into 
the end connector 
channels. The hole 
for the adjusting block should be positioned 
towards the top of the bar.  Drill into CSK holes 
provided in end connector channel. Fix with the 
short CSK screws.  
 
 

 

 

 

 
 
Ensure the top rail brace is level. Drill into CSK 
holes provided in the end connector channel. Fix 
with the short 
CSK screws.  
(bag103SL 

 

preferably 
hand screw) 

 
 
 
 
 

Содержание SL2F

Страница 1: ...ckers Phillips Screwdriver 1x Blue Masking Tape 1x BAG GB W 1x BAG GB B 1 x Bumper Pack 6 1 x Clear Silicon 1 x Screen Fitting Instructions Checked by ___________________ Date ________________________...

Страница 2: ...with a noticeable defect NOTE a noticeable defect must be visible to the naked eye in normal daylight conditions standing at a distance of two meters Any imperfection that is not visible within the ab...

Страница 3: ...the required size as per size chart for 2 Wall Showers Shower Size Cut Measurement Cut the overall length from the longest point 2 Wall nominal measurement X Cut measurement 900 885 1000 985 1100 1085...

Страница 4: ...d must be compatible with anodised aluminium as well as the waterproofing being used 6 Ensure the glass receiver channel is located firmly over the base glazing channel The machine recess in the wall...

Страница 5: ...ss panels and infill all connections of channels must be sealed with clear silicon supplied 12 Locate the glass panel SL R into the glazing channel The top of panel SL R must be level with the top of...

Страница 6: ...ating the outside disc Ensure the bottom of the door clears the floor tiles 17 CRITICAL SEAL Remove dust and dirt first Seal the connection between the glass receiver channel and the base glazing chan...

Страница 7: ...receiver channels Use spatula to remove the excess silicon Remove the masking tape immediately after application 24 SLIDING DOOR GUIDE BLOCK Slide the door as far back in an open position as possible...

Страница 8: ...804 Revision By JST SLIDING SCREEN GUIDE BLOCK CODE ABS LQ GB LONG Linea Quattro Installed on base or prior to tiling CODE ABS LQ GB SHORT Linea Quattro Used when installing frameless screens CODE ABS...

Отзывы: