- 8 - 

Configuration tolerated under certain conditions

 

 

Installation in an unheated space with one duct (outlet or inlet, volume > 20m

3

FAN

 set to 

1

 (see Getting start section, page 14).

 

 

Possible consequences: 
- The negative pressure in the 
room due to the expulsion of 
the exterior air may result in air 
entering through the doors and 
windows. Provide an air inlet 
(same diameter as the ducts) 
from the exterior in order to 
avoid sucking air from the 
heated space. 
 
- Caution: in winter, the air will 
be colder than the air expelled 
by the water heater, resulting 
in a drop in temperature in the 
garage.  
 

 

* In warmer climates ducts may be reversed to provide cold air into an adjacent room for cooling. Connect 
(air in) from outside and (air out) into the adjacent room. NOTE: It is not recommended to reverse ducts 
(air out) into the room that the HPWH is installed. This will reduce the COP and increase the cooling of the 
room. 

 
 
 

 Unsuitable 

c

onfigurations 

 

 

Prohibited Ducting installation 

configurations 

Related risks 

 The water heater draws in air 

from a room containing a 
charged source of heat used to 
heat the room. 

Uses heat energy from a higher cost source. 

  Connection to mechanical 

ventilation 

The greasy vapour and dust that may flow through the ducts of the 
mechanical ventilation system can reduce the life time of your water 
heater. 

  Connection to the roof space  

 

If the insulation between the ceiling and the roof space is insufficient, 
this installation may result in heat loss from the house. In extreme 
cases, condensation may appear on the ceiling of the rooms beneath 
the cooled parts of the roof space.  
Risk of falling objects and aspiration of dust by the raised water heater 
in this configuration, that can reduce the life time of your water heater. 

 

 
Other prohibitions

:

  

 

There must be no Heat Pump Air Access connection between the device and a tumble dryer. 

- Avoid dusty rooms  
- Do not draw in air containing solvents or explosives 
- Do not connect the appliance to hoods evacuating fatty or polluted air 
- Do not install the water heater in a room that freezes 
- Do not place anything on the top of the water heater 
- Do not install in an attic 

 

 

 

Содержание ODYSSEO 2

Страница 1: ...MAINTENANCE AND USER MANUAL WARRANTY ODYSSEO 2 HEAT PUMP WATER HEATER USING NON HEATED AIR EN GUIDE TO BE KEPT BY THE USER...

Страница 2: ...TIME CLOCK CONTROL TIME OF USE TARIFF 240 volt supply with 2 amp protection connected to the black auxiliary wire and the time clock programmed in accordance with the time of use tariff hours Set HCH...

Страница 3: ...2 Getting started 14 Use 16 Control panel 16 Description of the pictograms 16 Description of the modes 17 Adapting the mode of your appliance to your needs 19 Recommendations Maintenance Repairs 20 Ad...

Страница 4: ...t in a manner that does not comply with our recommendations It is strictly forbidden to stack this product Acceptable positions Forbidden positions Safety instructions Installing and starting up heat...

Страница 5: ...pliance by a fan which ventilates the various parts including the evaporator As it passes through the evaporator the coolant evaporates and absorbs calories from the incoming air The compressor compre...

Страница 6: ...essure at 2m in the open dB A 37 Coolant fluid Nota R134a GWP Global Warming Potential is 1350 kg R134a 1 35 Certified performances at an air temperature of 7 C CDC LCIE 103 15A and 25Pa ducting Coeff...

Страница 7: ...ation of condensate 4 Fixed feet 13 Compressor permanent condenser 5 Cold water inlet 14 Evaporator 6 Pocket 15 Fan wiring 7 Sheath 16 Fan 8 Electric heating element ceramic element and mechanical saf...

Страница 8: ...nded room habitable space the heat released by the water heater is not lost near the exterior walls Do not install near bedrooms to avoid disturbance by the noise Examples of rooms Garage boiler room...

Страница 9: ...ased by washing machines and tumble driers Semi underground room recovery of free heat released by the floor and walls of the basement 2nd Configuration installation in a heated or unheated room with...

Страница 10: ...onfigurations Related risks The water heater draws in air from a room containing a charged source of heat used to heat the room Uses heat energy from a higher cost source Connection to mechanical vent...

Страница 11: ...TR valve removal requires approximately 150 mm for withdrawal AS NZS 3500 4 National plumbing drainage Hot Water Supply Systems Acceptable solutions Combustible Material It is recommended to not place...

Страница 12: ...ansion during heating and also pressure fluctuations A discharge pipe connected to the pressure relief valve is to be installed in a continuously downward direction and in a frost free environment WAR...

Страница 13: ...st be adjusted accordingly see Setting the regulation section page 15 The total head loss in the ducts and accessories of the air inlet and outlet must not exceed 150 Pa The head losses must be calcul...

Страница 14: ...nection to supply circuit isolation and protection The appliance must be earthed Never power the heating element directly The safety thermostat fitted to the electric backup must only be repaired in o...

Страница 15: ...ack auxiliary wire Set HCHP parameter to ON see page 15 setting the regulation The diagram shown is only the functional configuration Wiring details ie switching fusing method of isolation neutrals an...

Страница 16: ...the regulation After the compressor has been working for about 10 minutes the temperature at the air outlet is at least 3 to 4 C below that of the incoming air The water drips out of the drain of the...

Страница 17: ...OFF Default value OFF Connecting to ducts 0 corresponds to water heaters without ducts The regulation then adjusts the noise level of the fan In this configuration the heat pump stops working if the...

Страница 18: ...he electric resistor Electric backup working Flashes slowly Time of use hours or Peak hours In TOU peak hours mode the symbol corresponding to the mode is displayed Risk of shortage of hot water In EC...

Страница 19: ...s mode is selected when the cursor is positioned above the icon AUTO mode This mode automatically selects the energy source for maximum savings while guaranteeing that the water is sufficiently hot Th...

Страница 20: ...be reset by pressing at the same time Automatic defrost The water heater is fitted with a defrost function In negative temperatures the water heater is automatically defrosted by opening a solenoid w...

Страница 21: ...X 55 9 7 X 62 Switching to AUTO mode is recommended if the temperature of the inlet air may drop below the lower operating limit at night see Selecting the location page 6 AUTO mode guarantees a given...

Страница 22: ...the closest hot taps are closed and power may be turned on again to the completely filled water heater In the event of an anomaly the heater does not heat or steam is released from the Pressure Temper...

Страница 23: ...check the seal again for leaks and slightly tighten the bolts if necessary Check the electric connections Check that the temperature sensor is properly positioned in the pocket near the electric backu...

Страница 24: ...temperature sensor faulty Sensor cut out or shorted Hot gas valve fault Fan fault Defrost function compromised Risk of damage to the compressor AUTO mode heating with the electric backup ECO mode no...

Страница 25: ...ach actuator is automatically deactivated after 3 minutes to avoid damaging the appliance Certain faults are diagnosed by the regulation which informs the user using error codes In this case refer to...

Страница 26: ...eset the thermostat safety device on the steatite resistor item 8 on page 5 Electric thermostat faulty Replace the thermostat The electric backup does not work Resistor faulty Replace the resistor Wat...

Страница 27: ...pare parts When ordering from one of the brand s resellers specify the precise type of water heater and the year of manufacture All this information can be found on the identification plate on the rea...

Страница 28: ...asia Pty Ltd in the form of exchange or supply free of charge excluding all labour and transport replacement charges 7 Warranty period for exchanged or supplied parts unit takes end at same time as ap...

Страница 29: ...ent protection system normally only found in major installations in contact with water such as gas transmission pipelines It is important that the composition of water is not excessively high in salt...

Страница 30: ...t least includes an exhaust valve Do not obstruct the exhaust valve s discharge outlet The exhaust valve s discharge pipe must be connected to the waste water system 3 Be careful not to reverse the ho...

Страница 31: ...4 Incoming air sensor 5 Evaporator sensor 6 Pocket sensor 7 Anti corrosion protection 8 1 800W steatite backup 9 Pocket 10 Mechanical safety device 11 Hot gas solenoid 12 Compressor condenser 13 Comp...

Страница 32: ...s parts 2 years in domestic installations 1 year in commercial installations The warranty covering service items or replacement unit expires at the end of the original purchase warranty period see det...

Отзывы: