Recommended configurations
1
st
Configuration
:
installation without ducts in an unheated space (Volume > 20m
3
)
FAN
set to
0
(see
Setting the regulation
section, page 15).
Examples of unheated rooms:
- Garage: recovery of free heat released by the car engine after use or by other household
appliances.
- Laundry
: dehumidification of the room and recovery of heat released by washing machines and
tumble driers.
-
Semi-underground room: recovery of free heat released by the floor and walls of the basement.
2
nd
Configuration
:
installation in a heated or unheated room with ducts
FAN
set to
2
(see Getting start section, page 14).
Recommendations:
Comply with the maximum duct lengths (see
Air
connections section, page 11).
-
Use thermally insulated rigid or semi rigid ducts
-
Provide air flow grills at the duct inlet and outlet to prevent entry of foreign bodies
-
Ensure that grills do not impede necessary air flow by being obstructed