X
55
If you did not manage to resolve your problem, contact your distributor/installer; have the
appliance's references with you.They are located on the side of the appliance. Measure the
temperature in the room.
The Commercial code (C) and the Serial number (E) provide the manufacturer's identi
fi
ca-
tion of the appliance you have just bought.
A
Standards, quality labels
B
Trade mark
C
Commercial code
D
Manufacturing reference
E
Serial No.
F
Manufacturer's No.
6
A
B
C
D
E
F
(photo non contractuelle)
Technical characteristics measured and calculated according to
REGULATION (EU) 2015/1188.
Model references
promSH-BD3.3-promSV-BD3.3-promSP-BD3.3
Characteristic
Symbol
Value
Unit
Heat output
Rated heat output
P nom
1.0 to 2.0
kW
Minimum heat output
P min
0.0
kW
Maximum continuous heat output
P max,c
2.0
kW
Auxiliary electricity consumption
At rated heat output
el max
0.000
kW
At minimum heat output
el min
0.000
kW
In standby mode
el sb
0.00095
kW
el sb
0.95
W
Type of heat output / room temperature check
Characteristic
Unit
Additional information
Electronic room temperature check and
weekly programmer
yes
Other inspection options
Room temperature check, with presence
detector.
no
Room temperature check, with open window
detector.
yes
Remote control option.
yes
Adaptive activation control.
yes
Activation time limiter.
no
Black globe sensor.
no
Contact details
Idem last cover page
corp_U065-7474-B-DIVALI-VERRE-PREMIUM Page 55