4.2.4.
Connection to a C13 or C33 vent (G20 and G25 only)
C13 type connection:
Air intake and gas evacuation via separate ducts connected to a horizontal
concentric terminal (vent).
C33 type connection:
Air intake and gas evacuation via separate ducts connected to a vertical
concentric terminal.
!
IMPORTANT:
The use of the “Horizontal air vent” accessory is mandatory to connect
a CONDENSINOX boiler with a concentric C13 vent.
The use of the “Black vertical air vent” or "Ochre vertical air vent"
accessory is mandatory to connect a CONDENSINOX boiler with a
concentric C33 vent.
fi
gure 4 - C13 type connection
fi
gure 5 - C13 type connection
The dimension A indicates the upper
position of the boiler exhaust outlet
A min
L
A
L