Line
Function
Setting range
or display
Setting
increment
Basic
setting
800
S
Reduced setpoint increase start
-30... 10 °C
1 °C
--
801
S
Reduced setpoint increase end
-30... 10 °C
1 °C
-5 °C
830
S
Mixer valve boost
0... 50 °C
1 °C
0 °C
834
S
Actuator running time
30... 873 s
1 s
240 s
850
I
Floor curing function (
figure 47
)
Off
- Off: Early interruption of the current program, program inactive.
- Functional heating.
- Heating ready for occupation.
- Functional h Curing heating.
- Curing h Functional heating.
- Manually: Manual mode enables you to programme your own concrete slab drying time.The function ends
automatically after 25 days.
"
Please comply with the
standards and instructions
of the manufacturer of
the building ! A good
performance of this function
is only possible with an
installation correctly
implemented
(hydraulic,
electricity and adjustments) !
This function can be stopped
by anticipation when setting
the adjustment on "Stop" .
50
45
40
35
30
20
5
0
25
55
1
1
5
7
X
10
18
25
15
1
figure 47 - Diagram of the concrete slab drying programmes
Heating flow temperature °C
Operational h Heating ready for occupation
Heating ready for occupation
Jour
Operational
heating
851
I
Floor curing setpoint manually
(if line 850 = manual)
0... 95 °C
1 °C
25 °C
This function enables you to set the custom concrete slab drying temperature. This temperature remains fixed.
The concrete slab-drying programme stops automatically after running for 25 days.
856
I
Floor curing day current
0 32
857
I
Floor curing day completed
0 32
900
S
Operating mode changeover
None, Protection mode,
Reduced, Comfort, Automatic
1
Reduced
Operating mode at end of concrete slab drying period
Installation and operating manual "1572 - EN"