2 .11 .6 Electrical connections
on the 3- phase outdoor unit side
Access to the connection terminals.
- Remove the front panel. Remove the screws and the
front panel.
- Make the connections in accordance with the diagram
figure 37, page 26
- Use cable clamps to prevent the conductors from
being disconnected accidentally.
- Fill in the space where the cables enter the outdoor
unit with the insulating plate.
figure 35 - Access to 3-phase outdoor unit’s
terminal block
figure 36 - Connections to 3-phase outdoor unit’s
terminal block
figure 37 - Finalisation of connection
to 3-phase outdoor unit
figure 38 - Location of electrical cables and
refrigeration connections to 3-phase outdoor unit
Remove the screws
and push downwards
Front panel
Terminal
block
Cable
clamps
Cables
(supply and
interconnection)
1
INDOOR UNIT
POWER
2 3 L1 L2 L3 N
Terminal
block
Interconnection between
the outdoor unit and the
hydraulic unit
General electrical
supply
Front
Underneath
Lateral side
Back
Installation and operating manual "1572 - EN"
- 31 -
Heat pump air/water split 2 services alféa excellia duo