- 28 -
User manual 1634 - EN
Loria 6000 heat pump
8 ERP performance values
8 1
ERP definition
"ERP" includes two European directives that are part of the programme for the global reduction of greenhouse gas emissions:
-
The eco-design directive sets efficiency thresholds and prohibits the sale of any product with an efficiency lower than the set thresholds.
-
According to the labelling directive, energetic efficiency shall be displayed to encourage end users to purchase energy-efficient products.
8 2
ERP Specifications
Trade name / Product name:
atlantic /
Loria 6004
Loria 6006
Loria 6008
Loria 6010
Reference
522911
522912
522913
522914
Heating ranges
35°C
55°C
35°C
55°C
35°C
55°C
35°C
55°C
Air/water heat pump
Yes
Equipped with a supplementary heater
Yes
Average climate - Space heating characteristics
Energy class
(a)
-
-
A++
A+
A++
A++
A++
A+
A++
A++
Rated heat output
(2)
P
rated
kW
4
4
6
5
7
6
9
7
Seasonal heating energy efficiency
ƞ
s
%
181
127
186
128
166
125
154
116
Seasonal efficiency for package with outdoor temperature
sensor
(1)
ƞ
s
%
183
129
188
130
168
127
156
118
Seasonal efficiency with room unit
(1)
ƞ
s
%
185
131
190
132
170
129
158
120
Annual energy consumption
Q
he
kWh
1884
2708
2588
2933
3226
4197
4481
5256
Colder climate - Space heating characteristics
Rated heat output
(2)
P
rated
kW
NA
Seasonal heating energy efficiency
ƞ
s
%
Annual energy consumption
Q
he
kWh
Warmer climate - Space heating characteristics
Rated heat output
(2)
P
rated
kW
5
5
6
6
7
7
12
8
Seasonal heating energy efficiency
ƞ
s
%
221
160
242
153
211
154
201
130
Annual energy consumption
Q
he
kWh
1270
1793
1201
1936
1866
2349
3040
2990
Acoustic values
Sound power level of hydraulic unit
L
WA
dBa
44
44
44
44
Sound power level of outdoor unit
L
WA
dBa
62
62
69
68
Declared capacity for heating for part load at indoor temperature 20°C and outdoor temperature Tj
Tj = -7°C
Pdh
kW
3,7
3,8
5,2
4,1
5,8
5,7
7,5
6,6
Tj = +2°C
Pdh
kW
2,4
2,5
3,5
2,7
3,4
3,4
4,6
4,0
Tj = +7°C
Pdh
kW
2,0
1,4
1,9
1,8
2,5
2,3
3,2
3,2
Tj = +12°C
Pdh
kW
2,3
2,1
2,4
2,1
2,2
2,0
3,8
3,5
Tj = bivalent temperature
Pdh
kW
3,7
3,8
5,2
4,1
5,8
6,3
7,5
6,6
Tj = operation limit temperature
Pdh
kW
3,4
3,2
4,8
3,9
6,0
4,7
6,9
6,1
Bivalent temperature
T
biv
°C
-7
-7
-7
-7
-7
-7
-7
-7
Degradation coefficient (3)
(3)
Cdh
-
0,9
0,9
0,9
0,9
0,9
0,9
0,9
0,9
Declared coefficients of performance for part load at indoor temperature 20°C and outdoor temperature Tj
Tj = -7°C
COP
d
-
3,0
2,0
3,0
1,9
2,6
1,8
2,4
1,8
Tj = +2°C
COP
d
-
4,5
3,2
4,6
3,2
4,1
3,2
3,9
2,8
Tj = +7°C
COP
d
-
6,4
4,4
6,1
4,4
5,7
4,3
5,3
4,4
Tj = +12°C
COP
d
-
8,7
6,5
9,3
6,5
7,8
5,8
7,3
4,9
Tj = bivalent temperature
COP
d
-
3,0
1,9
2,8
1,9
2,6
1,8
2,4
1,8
Tj = operation limit temperature
COP
d
-
2,6
1,6
2,8
1,8
2,4
1,5
2,2
1,6
For air-to-water heat pumps: temperature operating limit
TOL
°C
-10
-10
-10
-10
-10
-10
-10
-10
Water temperature operating limit
WTOL
°C
55
55
55
55
55
55
55