Loria 6010

Loria 6004

Loria 6006

Loria 6008

FR NL DE EN PL

ES PT

IT

PT PT

Air/water heat pump 

single service split system

Loria 6000

atlantic-comfort.com

Subject to modifications without notice.

Document not binding.

Document No. 1634-4 ~ 26/04/2016

Содержание 522911

Страница 1: ...for future reference Loria 6010 Loria 6004 Loria 6006 Loria 6008 FR NL DE EN PL ES PT IT PT PT Air water heat pump single service split system Loria 6000 atlantic comfort com Subject to modifications without notice Document not binding Document No 1634 4 26 04 2016 ...

Страница 2: ...nd setting the DHW TIME PROGRAMME 14 Regulation parameters 16 Overview 16 Setting parameters on the user interface 16 List of End User parameters 16 Information and troubleshooting 18 Displaying information 18 Hydraulic unit errors 18 Outdoor unit errors 20 Maintenance 20 Regular checks 20 Outdoor unit check 20 Holiday mode 25 Standby mode 26 Exemption function Boost button 26 Information screen K...

Страница 3: ...es Nothing should obstruct the air from circulating through the evaporator and out of the fan The outdoor unit must only be installed outdoors If a shelter is required it must have broad openings on all 4 walls and comply with the installation clearances check with your installer Do not climb on the top of the outdoor unit The room in which the appliance is operating must be correctly ventilated i...

Страница 4: ...cycles to be conducted efficiently 2 1 Precautions and warnings regarding your installation 2 1 1 The outdoor unit The outdoor unit contains the equipment for capturing energy from the ambient air Your installer has placed this unit in a location that enables it to operate in an optimum manner Nothing should obstruct the air from circulating through the evaporator and out of the fan The water cont...

Страница 5: ...n coil heaters Domestic hot water DHW figure 1 Overall view of the configuration of a complete installation 2 2 End of life of the device The apparatus must be dismantled and recycled by a specialised service provider The apparatus must never be disposed of with household waste large objects or in a landfill When the apparatus reaches its end of life please contact you installer or the local repre...

Страница 6: ...lines Configure the modifiable values after pressing OK to confirm 4 Information ESC output Access the information menu the icon appears Exit the menu currently displayed Cancel a modification being made 5 Configuration Access the user level press and release the icon appears List of parameters see 4 3 page 16 Access the installer level press and hold for more than 5s the icon appears 6 OK Confirm...

Страница 7: ...e set in the User interface or programme set on the room thermostat Constant mode with reduced temperature setpoint or Constant mode for heating or cooling with comfort temperature setpoint Holiday mode heating only The use concerned is in Off mode area 1 2 DHW Read information Access the Installer settings 1 Frost protection provided that the electric power supply to the HP is not switched off 2 ...

Страница 8: ...r has commissioned your installation Set the current date and time see 3 3 2 Select the programming mode for heating and for cooling if your installation is equipped with the cooling kit see 3 3 3 page 10 Set the temperature setpoints where necessary see 3 3 4 page 12 Select the DHW programming mode if the installation is equipped with a domestic hot water tank and electrical back up see 3 4 page ...

Страница 9: ...the time The hour display flashes 3 Press the or button to set the hour 4 Press OK to confirm The minutes display flashes 5 Press the or button to set the minutes 6 Press OK to confirm The settings are saved 7 Press the or button to change other settings or the 8 Press to return to the basic display 3 5 7 8 1 2 4 6 3 3 2 Time setting User manual 1634 EN Loria 6000 heat pump ...

Страница 10: ... press the MODE button several times OK Selecting the desired mode for the use displayed PROG mode Automatic switching comfort reduced heating depending on the time programme Description of the other modes or constant comfort mode heating or cooling Constant reduced mode Holiday mode Off mode for the use concerned OK Confirming the adjustment Press OK Note When browsing the temperature setpoints c...

Страница 11: ...ct the day s 1 Monday 2 Tuesday 3 Wednesday 4 Thursday 5 Friday 6 Saturday 7 Sunday 10 Mon Sun 8 Mon Fri 9 Sat Sun E g 8 Monday to Friday OK No 12 OK start of comfort heating Start up time for the 1st heating phase E g 06 00 OK No 13 OK end of comfort heating Shutdown time for the 1st heating phase E g 08 00 OK No 14 OK start of comfort heating Start up time for the 2nd heating phase E g 11 30 OK ...

Страница 12: ...ECO setpoint is set to 18 C OK Set the temperature setpoint using the following buttons to increase the setpoint to decrease the setpoint E g 17 C Press OK to confirm Press to return to the basic display B Specific case direct access to the current mode and use setpoints OK E g Current use heating of area 1 Current mode PROG comfort phase The current setpoint comfort is 20 C OK Set the temperature...

Страница 13: ... 13 User manual 1634 EN Loria 6000 heat pump ...

Страница 14: ... programme Description of the other modes Constant comfort mode Constant reduced mode Off mode for DHW OK Confirming the adjustment Press OK Notes When browsing the temperature setpoints can be modified at any time using the or buttons Press OK to confirm Before exiting check that you have confirmed the desired mode In the event of extreme outdoor temperatures the electrical back up system of the ...

Страница 15: ... 4 Thursday 5 Friday 6 Saturday 7 Sunday E g 10 Monday to Sunday OK No 26 OK start of comfort heating Start up time for the 1st heating phase E g 00 00 OK No 27 OK end of comfort heating Shutdown time for the 1st heating phase E g 07 00 OK No 28 OK start of comfort heating Start up time for the 2nd heating phase E g 13 30 OK No 29 OK end of comfort heating Shutdown time for the 2nd heating phase E...

Страница 16: ... 13 1st phase of the selected day end of comfort 00 15 24 00 22 00 14 2nd phase of the selected day start of comfort 00 00 23 45 15 2nd phase of the selected day end of comfort 00 15 24 00 16 3rd phase of the selected day start of comfort 00 00 23 45 17 3rd phase of the selected day end of comfort 00 15 24 00 1 These parameters or menus may not appear They depend on the appliance s configuration o...

Страница 17: ...ations are applied to the whole week 26 1st phase of the selected day start of comfort 00 00 23 45 00 00 27 1st phase of the selected day end of comfort 00 15 24 00 05 00 28 2nd phase of the selected day start of comfort 00 00 23 45 14 30 29 2nd phase of the selected day end of comfort 00 15 24 00 17 00 Heat pump 45 Switch from summer winter according to the outdoor temperature 15 30 C 18 C When t...

Страница 18: ...e 5 Holiday mode 6 Controlled by the room thermostat 7 Frost protection activated 8 Floor drying mode 9 Rate input activated No Value DHW status 16 0 Pending 1 Comfort mode charge activated 2 Reduced mode charge activated 3 Legionella charge 4 Frost protection activated 5 Forced operation 5 2 Hydraulic unit errors The faults or breakdowns of the hydraulic unit are reported on the display unit of t...

Страница 19: ...hen defrosting the outdoor unit temperature 3 C 181 Appliance shutdown if the error 53 occurs 3 times in 1 hour 55 Frost protection of the HP circuit activated with electrical back up 56 Frost protection of the DHW tank activated with electrical back up 62 Load shedding peak shaving or rate input activated 66 Outdoor unit error external cause See 5 3 Outdoor unit errors page 20 67 DHW cycle too lo...

Страница 20: ... sensor error 13 8 Flashes 4 Flashes Current current error 14 8 Flashes 6 Flashes 3 Flashes Pressure sensor error pressure switch error 15 9 Flashes 4 Flashes 13 Flashes Current sensor error permanent shutdown 16 9 Flashes 5 Flashes 14 Flashes Detection error for the position of the compressor rotor permanent shutdown 15 Flashes Compressor start up error permanent shutdown 17 9 Flashes 7 Flashes 1...

Страница 21: ... 21 7 Room thermostat UA55 optional C mode prog boost User manual 1634 EN Loria 6000 heat pump ...

Страница 22: ... 2 3 4 6 5 18 30 19 5 C 7 Day Clock MODE programming activated phase 3 in progress Temperature measured in the room Current status heating in demand if flashing 7 1 Room thermostat and description of the display 7 2 Commissioning WITH room thermostat Once your installer has commissioned your installation On the room thermostat Set the current date and time see 7 2 1 page 23 Select the automatic mo...

Страница 23: ...Press or to change the day e g Tuesday set 2 5 To save the data and exit the settings menu press the adjustment knob 7 2 2 Mode selection Selecting the MODE To select the mode press the MODE button several times Automatic mode temperature set according to the time programme see 7 2 3 page 24 1 2 3 4 6 5 19 32 20 0 C 2 Holiday mode temperature set for a given number of days see 7 2 5 page 25 9 14 0...

Страница 24: ...ogramme for the weekend Saturday to Sunday Day 6 and 7 2 phases 7 30 a m at 20 5 C and 11 p m at 18 C In this example phases 1 and 6 must be modified and phases 2 to 5 must be deactivated 18 C 20 C 20 5 C 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 0 1 2 3 4 5 6 7 Day 6and7 Ph 1 Ph 5 deactivated Ph 2 deactivated Ph 1 Ph 6 Ph 3 deactivated Ph 4 deactivated Day 6 Day 7 1 Press the knob to chan...

Страница 25: ...ant mode setting the temperature setpoint Reminder the default temperature displayed corresponds to the temperature measured in the room e g 19 5 C 1 Turn the knob to set the initially recorded setpoint e g 20 C 2 Press the t flashes then turn the knob 3 to set the desired room temperature e g 22 C 4 Press the knob to confirm The display returns to the temperature measured in the room and to const...

Страница 26: ... tank Holiday settings number of days Holiday settings holiday temperature Press the mode button to exit the information screen or if no setting is made for 1 minute the screen automatically returns to the basic display The DHW tank is heated to reach the comfort setpoint 7 2 7 Exemption function Boost button Press the boost button to access the exemption functions Press and release heating or coo...

Страница 27: ...oom thermostat see 3 3 3 page 10 With room thermostat see 7 2 5 page 25 In the event of shutdown for an extended period or an unknown period of time set the appliance to off or standby mode Without room thermostat see 3 3 3 page 10 With room thermostat see 7 2 6 page 26 7 3 2 Stopping the DHW Set to off mode see 3 4 page 14 User manual 1634 EN Loria 6000 heat pump ...

Страница 28: ...iciency ƞs Annual energy consumption Qhe kWh Warmer climate Space heating characteristics Rated heat output 2 Prated kW 5 5 6 6 7 7 12 8 Seasonal heating energy efficiency ƞs 221 160 242 153 211 154 201 130 Annual energy consumption Qhe kWh 1270 1793 1201 1936 1866 2349 3040 2990 Acoustic values Sound power level of hydraulic unit LWA dBa 44 44 44 44 Sound power level of outdoor unit LWA dBa 62 62...

Страница 29: ...ty control Inverter For air to water heat pumps rated air flow rate outdoors m3 h 2070 2340 3600 6200 a The energy class is that of the product The energy class scale for products is limited to class A until 2019 1 The detailed calculations are available on the package sheet The room appliance refers to the sensors room thermostats and offset controllers included or not included in the kits 2 For ...

Страница 30: ...s of the building range 55 C A A G F E D C B A A 30 30 34 36 75 82 90 98 125 150 Product name Loria 6004 Loria 6006 Loria 6008 Loria 6010 Reference 522911 522912 522913 522914 Seasonal space heating energy efficiency of heat pump 124 128 123 114 Type of control outdoor sensor Room appliance Class II Class VI Class II Class VI Class II Class VI Class II Class VI Bonus 2 4 2 4 2 4 2 4 Seasonal space...

Страница 31: ... 31 User manual 1634 EN Loria 6000 heat pump ...

Страница 32: ...r health or on the environment Reprocessing of the refrigerant lubricant and other parts may be performed by a qualified installer in compliance with the local and national legislation in force This unit must be recycled by a specialised service and in no case may it be thrown away with household waste rubble or in a landfill Please contact your installer or local representative for more informati...