17
1) Location of the device
-This device was designed to be installed in resi-
dential premises. In any other case, please call
your distributor.
-Installation must comply with the standards cur-
rently enforced in the country of use.
-Locate the device within minimum distances
from obstacles.
do not install the device in a draft likely to
affect its control (
under centralised mecha-
nical ventilation, etc…
).
do no install it under a fixed mains outlet.
do not install shelf above the device.
In order to avoid a hazard for very young children, this device should
be installed so that the lowest heated rail is at least 600 mm above
the floor.
i
nSTaLLing The deviCe
volume 1
No electrical device
volume 2
Electrical
device
IPX4 (Standard EN
60335-2-43
: 2003/A2: 2008)
150
mini
281 mini
150
mini
200 mini
Panel heater cable
Live=brown
Neutral=blue
LIVE
NEUTRAL
Electricity
grid
Two possible cases
Pilot wire=Black
1st case: only one heater
2nd case: multiple heaters
The pilot wire end is insulated
and not further connected
The pilot wire of all heaters in a
control group, up to a maximum
of 20 units with any one them used
as the Master, are connected
by a 1.0mm
2
220-240V insulated cable
2) Connecting the device
gB