18
3) Programming
The device can be controlled remotely if its pilot wire is connected to
a device fitted with a programmer, a programming unit or an energy
management unit.
This device must be installed with a remotely controllable
programming system. This type of system can be connected
via the pilot wire of the device.
Chart indicating the orders the device can receive over its
pilot wire
(
to be measured between the pilot wire and the neutral
).
Orders received Current absent
Full alternance
230V
Negative half-
alternance
-115V
Positive half-
alte115V
Ref/neutral
oscilloscope
Mode achieved
CONFORT
ECO
STANDBY
STOP LOAD
SHEDDING
Heating
temperature
CONFORT
setting
3°C to 4°C
below
CONFORT
setting
Standby
temperature,
about 7°C
Stopping the hea-
ting immediately.
Can also be used
for load shedding.
-The device must be supplied with 230V, 50Hz.
-Mains connection must be ensured using the 3-wire cable factory
fitte to the heater , through a connecting box. In damp premises, such
as bathrooms and kitchens, install the connecting box at least 25cm
from the ground.
-The installation must comply with local national regulation. If in
doubt, ask the national Atlantic distributor.
-Ground connection is forbidden.
do not connect the pilot wire (
black
) to ground.
-If power cable is damaged or too short, to avoid any danger it must
be replaced by a qualified electrician using special tools.
-If a heater pilots or is piloted by a 30mA differential (
e.g. bathroom
),
the pilot wire supply must be protected on this differential.