- 49 -
►
Installed options
Installed options are con
fi
gured during commissioning (see
page 46
).
However, you can modify them by accessing the "
Installed Options
" menu.
Name of Appliance
- Choose the appliance's power.
Electrical backup
- Choose the electrical backup power.
Boiler connection
- If the electrical backup is set to "
No
", you can then set the boiler connection to "
Yes
".
- If a power setting is applied to the electrical backup, the boiler connection setting
remains set to "
No
" and cannot be changed.
Number of Circuits
- Choose the number of circuits.
Cooling
- If the installation is
fi
tted with cooling function, choose the zone(s):
None / Area 1 / Area 2 / Area 1 and 2
.
Name of Appliance
-- KW
Number of circuits
2
3 KW
Electrical back-up
Area 1
Cooling
Boiler connection
No
Installed options
Complete
Installed options
Hydraulic con
fi
guration
Area 1
►
Hydraulic con
fi
guration
▼
Heating / Cooling
- Choose the heating zone to con
fi
gure.
Hydraulic con
fi
guration
Area 1 (Direct circuit)
Area 2 (Mixed circuit)
Hot water
Alfea Extensa A.I. R32 / INSTALLATION / 2114 - EN