background image

12

NOTE

: Once you select the start button an audible exit alarm will begin to sound and the 

Sanidyne

®

 

Prime Remote

 

will begin counting down from 1:30 seconds to allow all inhabitants to leave the area before the UV treatment begins. The 

words “LEAVE AREA

” will now appear on the lower status bar of the Hand-held Remote Controller. (See Figure 3, for 

the specific location). The occupancy Sensors located on the top of the unit (Shown on Figure 1) provide an additional 

safety area around the unit will begin to operate at this time. If the sensors detect movement close to the 

Sanidyne

®

 

Prime Remote

 when less than 30 seconds remains on the countdown time, the 

Sanidyne

®

 

Prime Remote

 will 

automatically reset giving 30 seconds more to leave the Operation Area. The Countdown time as well as the Treatment 

Time will all be displayed on the Hand-held Remote Controller. See Figure 3, for the specific location.

Occupancy Sensors do not protect the entire Operation Area of the 

Sanidyne

®

 

Prime Remote

. Under no 

circumstances should this unit be permitted to operate with human, or animals present in the Operation Area.

 

4. 

The Hand-held Remote Controller displays the Lamp Status; When the lamp operation indicators on the display glow yellow 

the lamp is on, when the lamp is off it displays grey. (See 

Figure 3

 to locate lamp operation indicators) Once the treatment 

time has expired the unit will turn off the Germicidal Ultraviolet Lamps and it is now safe to return to the area. 

If at any time during the Treatment Time the Occupancy Sensors detect someone near the

 

Sanidyne

®

 

Prime Remote

, the unit will immediately turn off and send an alarm to the Hand-held Remote Controller and 

the 

Sanidyne

®

 

Prime Remote

. If this event occurs the alarm can be turned off on the remote by pressing anywhere on the 

display or at the 

Sanidyne

®

 

Prime Remote

 

by pressing the START/STOP

 on the Keypad. If the Alarm is turned off at the 

Sanidyne

®

 

Prime Remote

 

the operator can reset the unit by pressing the START/STOP button on the keypad controller 

again to begin the 1:30 countdown to allow all inhabitants to leave the area. After the 1:30 has elapsed the unit will power 

on and complete the remaining Treatment Time left prior to the alarm.

If the Hand-held remote is used to stop the alarm, the operator must return to the area and ensure that the area is safe 

to proceed. Select theSTART/STOP button on the keypad controller to begin the 1:30 countdown to allow all inhabitants 

to leave the are. After the 1:30 has elapsed the 

Sanidyne

®

 

Prime Remote

 

will power on and complete the remaining 

Treatment Time left prior the alarm.

s

etting

 D

ate

 

anD

 t

ime

1.  Press the 

Settings

 Button.

2.  Press 

Set Date/Tim

e.

3.  Press 

Admin Pin

. Using keyboard enter Pin number 1234.

4.  Press 

Date

 or 

Time

.

5.  Scroll in 

Date

 or 

Time

 by swiping the scroll bar.

6.  Press 

Done

. Then press 

Home

 button when finished.

s

aving

 

a

 s

ession

Saving a Session:  At the end of a Session or after a Session is Stopped the 

“Save This Session”

 box will appear.

To save a Session;

1.  Press 

Yes

 under Save Session.

2.  Press on 

Note Entry

3.  Type in Session Notes, press 

OK

Clearing Total Op Time or Clearing Session Data:

1.  Press 

Settings

 Button

2.  Press 

Settings

3. 

Press on the box next to 

“Reset Total Operating Time”

 and/or 

“Clear Session Data.”

4.  Press 

Home

 Button

Содержание Sanidyne 40-0634A

Страница 1: ...duct Information Available at Ultraviolet com BuyUltraviolet com Read and Follow All Safety Instructions Save These Instructions Installation Operation Maintenance 8 High Output UV Lamps with ArmorLit...

Страница 2: ...NTENANCE LOG 17 19 USER ASSISTANCE 20 Patent Notice 20 WARRANTY PRODUCT REGISTRATION 20 These instructions generally describe the installation operation and maintenance of the Sanidyne Prime Remote Po...

Страница 3: ...3 Read and follow all notices and warnings on the sanitizer 14 SAVE THESE INSTRUCTIONS SAFETY WARNINGS All personnel should be alerted to the potential hazards indicated by the product safety labeling...

Страница 4: ...equipment for use in the user s system or process No warranty or representation is made by the manufacturer with respect to suitability or performance of this equipment or to the results that may be...

Страница 5: ...ovide direct germicidal ultraviolet exposure for air and surface disinfection in unoccupied areas to disinfect and prevent areas and surfaces from microorganisms Ultraviolet disinfection dosage is a f...

Страница 6: ...de until ready for installation Carefully inspect all packing materials to prevent the loss of accessories spare parts or instructions Do not discard packing materials until unit is assembled checked...

Страница 7: ...is completed 2 Hour Buttons Up and down buttons are used to select treatment hours between 0 and 24 3 Minute Buttons Up and down buttons are used to select treatment minutes between 0 and 59 4 Start...

Страница 8: ...s three icons at bottom which are Sound Off Vibrate Sound On 2 Indicator Light Glows RED when the device begins to turn on and during device charging Turns GREEN when fully charged 3 Treatment Time Se...

Страница 9: ...to see percent of change 10 Settings Button Contains choices for a Settings Reset Operating Time or Clear Session Data b Set Date Time requires a PIN to reset See Setting Date and Time on Page 12 c S...

Страница 10: ...ns supplied with the Sanidyne Prime Remote on all access doors to the area where treatment operation will take place It is the users responsibility to post signs or notices for all personnel and perso...

Страница 11: ...econds remain on the countdown time the Sanidyne Prime Remote will automatically reset giving 30 seconds more to leave the Operation Area Occupancy Sensors do not protect the entire Operation Area of...

Страница 12: ...someone near the Sanidyne Prime Remote the unit will immediately turn off and send an alarm to the Hand held Remote Controller and the Sanidyne Prime Remote If this event occurs the alarm can be turne...

Страница 13: ...e Remote on each side of large fixed objects like a bed or table etc 2 Measure the longest distance from the Sanidyne Prime Remote to the farthest wall Use this length to compare to the Distance From...

Страница 14: ...S BETWEEN CUFFS AND GLOVES AND AN ULTRAVIOLET BLOCKING FACE SHIELD MUST BE WORN TO COVER AND PROTECT EYES AND EXPOSED SKIN NOTE STER L RAY lamps used in the Sanidyne Prime Remote have ArmorLiteTM Safe...

Страница 15: ...fied and factory authorized personnel Table 1 Troubleshooting Problem Possible Cause Corrective Action Sanidyne Prime Remote not operating Power disconnected Check connections Fuse not operating Remov...

Страница 16: ...ity Aging Measuring UV C Germicidal Fixture Leakage 2 Promate Safety Glasses Safety eyewear MUST be used as general purpose safety protection and for additional shielding from ultraviolet rays 3 Addit...

Страница 17: ...Part No Part No 1 STER L RAY Germicidal Lamp 05 0892 05 0892 2 SureliteTM Ballast 10 0138 10 0138 3 Power Cord 35 1754 35 1767 4 PromateTM Face Shield Adjustable Headgear 00 0126 00 0126 5 PromateTM W...

Страница 18: ...18 MAINTENANCE LOG Date Maintenance Performed Service Person Comment s...

Страница 19: ...19 MAINTENANCE LOG Date Maintenance Performed Service Person Comment s...

Страница 20: ...g warranties of merchantability and fitness for a particular purpose whether or not purposes or specifications are described herein We further disclaim any responsibility whatsoever to the customer or...

Отзывы: