background image

5

INSTALLATION

L

OCATION

1.

The water purifier is intended for indoor use only. The water purifier should be protected from the elements and 
from temperatures below freezing. The ambient temperature, in the area surrounding the water purifier, should be 
between 33

F and 100

F.

2.

Electrical power supplied to the water purifier 

MUST

match power requirements listed on the water purifier. Use 

of a voltage surge protector is recommended.

3.

Plug water purifier into an approved ground fault circuit interrupt (GFCI) receptacle.

4.

The water purifier should be located in a dry, well-lit area, which provides enough room to perform routine 
maintenance. This includes a minimum distance of one chamber length from the chamber end, to allow for 
cleaning and/or the changing of the lamp and quartz sleeve as well as a minimum of 6" on the opposite end of the 
water purifier.

5.

The water purifier should always be located closest to the point of use. This reduces the chance of the purified 
water being re-contaminated by bacteria in the water distribution system after the water purifier.

6.

CAUTION:

As with any water handling device, the water purifier should be located in an area where any possible

condensation or leakage from the water purifier, any purifier accessory and/or plumbing will not result in damage 
to the area surrounding the water purifier. For added protection, it is recommended that a suitable drain pan be 
installed under the purifier. The drain pan must be plumbed to an adequate, free flowing, drain to prevent water 
damage in the event of a leak. There are numerous leak detection/flood stop devices, available on the market today,
designed to stop the flow of water, reducing the chance of water damage due to leakage. For more details regard-
ing leak prevention and/or limiting damages due to leaks, please contact the factory.

7.

The water purifier should be located after all other water devices, such as De-ionizers, Water Softeners, Carbon 
Filters, Pre-Filters, Reverse Osmosis, Pressure Tanks, and Pumps. This reduces the chance of the purified water 
being re-contaminated by bacteria in any of these units.

D

IMENSIONAL

D

ATA

Figure 1 - Mighty



Pure

Dimensional Drawing

Table 2 - Mighty



Pure

Dimensional Data

Model:

A

B

C

D

E

F

G

H

Inlet/Outlet

MP13A

6"

13"

5-

3

/

4

"

7"

13-

1

/

2

"

3-

5

/

8

"

4-

15

/

16

"

8-

3

/

8

"

1

/

2

"m NPT

MP16A

8-

3

/

4

"

16"

8-

3

/

4

"

10"

16-

1

/

2

"

3-

5

/

8

"

4-

15

/

16

"

8-

3

/

8

"

3

/

4

"m NPT

MP22A

14-

3

/

4

"

22"

13-

1

/

4

"

14-

1

/

2

"

22-

1

/

2

"

3-

5

/

8

"

4-

15

/

16

"

8-

3

/

8

"

3

/

4

"m NPT

MP36C

28-

1

/

2

"

36"

16"

18"

36-

1

/

2

"

4-

15

/

16

"

5-

11

/

16

"

9-

1

/

2

"

1"m NPT

MP49C

40-

7

/

8

"

49"

26"

30"

49-

1

/

2

"

4-

15

/

16

"

5-

11

/

16

"

9-

1

/

2

"

1-

1

/

2

"m NPT

Содержание Mighty Pure MP13A

Страница 1: ...pauge NY 11788 USA 631 273 0500 Fax 631 273 0771 e mail info ultraviolet com Extensive Product Information Available at Document No 98 1123E1 Revised February 2007 1994 2007 Atlantic Ultraviolet Corporation www ultraviolet com ...

Страница 2: ... 16 19 Mighty Pure MODELS MP13A MP16A MP22A 16 17 Mighty Pure MODELS MP36C MP49C 18 19 USER ASSISTANCE 20 WARRANTY 20 PATENT NOTICE 20 These instructions generally describe the installation operation and maintenance of the Mighty Pure line of water purifiers Models MP13A MP16A MP22A MP36C and MP49C Questions that are not specifically answered by these instructions should be directed to the Factory...

Страница 3: ...o maintain good legibility Always replace illegible safety labels Contact factory to obtain replacement safety labels SAFETY INSTRUCTIONS WARNING To guard against injury basic safety precautions should be observed including the following 1 Read and follow ALL safety instructions 2 Do not use this water purifier for other than its intended purpose as described in this manual 3 Do not alter design o...

Страница 4: ...nd the exposure time The operation of the Mighty Pure is as follows 1 Water enters the purifier and flows into the annular space between the quartz sleeve and the chamber wall 2 Suspended microorganisms are exposed to the ultraviolet rays emitted by the germicidal lamp 3 The translucent sight port or optional ultraviolet monitor provides visual indication of germicidal lamp operation 4 Water leavi...

Страница 5: ...ny possible condensation or leakage from the water purifier any purifier accessory and or plumbing will not result in damage to the area surrounding the water purifier For added protection it is recommended that a suitable drain pan be installed under the purifier The drain pan must be plumbed to an adequate free flowing drain to prevent water damage in the event of a leak There are numerous leak ...

Страница 6: ...he steps in Lamp Installation or Replacement section CAUTION Lamp and quartz sleeve are easily damaged Exercise care when installing lamp 10 Once the plumbing hook ups are made it is a good practice to disinfect the downstream plumbing between the purifier and point of use This is done by introducing chlorine into the purifier chamber a 100 ppm solution of chlorine is suggested With the chlorine i...

Страница 7: ...to the rated capacity of the purifier The flow control valve is located in line prior to the water purifier and should be protected from ultraviolet exposure by the use of a 90 degree elbow fitting between the flow control valve and the water purifier 5 Audio Alarm Activated by the Ultraviolet Monitor or Safety Sensor alerts the user to any malfunction detected 6 Solenoid Valve Operated in conjunc...

Страница 8: ...purifiers so equipped the Guardian Ultraviolet Monitor provides visual indication of the ultraviolet intensity through the quartz sleeve and water in the purifier chamber 2 To ensure proper operation of the water purifier regular biological testing should be performed on a schedule recommended by local public health authorities or at minimum at installation quarterly for the first year of service ...

Страница 9: ...ully remove lamp socket on end now exposed 5 Next carefully slide lamp back into chamber until approximately 2 inches of the lamp is exposed on the opposite end Hold lamp and remove lamp socket 6 Lamp should now be disconnected on both ends Carefully remove lamp from chamber Be sure to withdraw lamp straight out without angling until completely clear of quartz sleeve CAUTION Lamp and quartz sleeve...

Страница 10: ...OTE It is advisable to support the quartz sleeve on the opposite end with your finger so that it does not drop to the bottom of the chamber as it slides into the chamber 7 Once the quartz sleeve is removed clean with alcohol or a mild non abrasive detergent Stubborn stains usually can be removed with a dilute hydrochloric acid NOTE Follow all manufacturer s instructions and precautions when handli...

Страница 11: ...quartz fragments from the interior of the chamber 8 Carefully discard all pieces of the broken quartz sleeve 9 Align the end of the replacement quartz sleeve with the gland fitting of the chamber 10 Carefully slide the quartz sleeve into the chamber guiding it through the gland fitting NOTE Use care to keep the quartz sleeve parallel to the chamber Angling the quartz sleeve in any direction could ...

Страница 12: ...icing the sensor probe to work in a clean dry area 6 Once the quartz rod is removed clean with alcohol or a mild detergent and rinse with clean water Stubborn stains usually can be removed with a dilute hydrochloric acid NOTE Follow all manufacturer s instructions and precautions when handling chemicals Once the quartz rod has been cleaned handle the rod by the sides to avoid getting fingerprints ...

Страница 13: ... sealing tape and reinstall Quartz sleeve fouled Clean quartz sleeve see Quartz Sleeve Cleaning or Replacement in the Maintenance section Sensor Probe if equipped Clean lens or Quartz Rod see Optional Ultraviolet lens fouled Monitor Sensor Probe Cleaning in the Maintenance section Poor purifier performance Germicidal lamp output Replace lamp as it nears its end of life EOL See AND OR Low UV intens...

Страница 14: ... 50 Watts Max Operating Pressure 100 PSI 100 PSI 100 PSI 100 PSI 100 PSI Ambient Temperature 33 F 100 F 33 F 100 F 33 F 100 F 33 F 100 F 33 F 100 F Quartz Sleeve 1 1 1 1 1 Drain Plug 1 4 NPT 1 4 NPT 1 4 NPT 1 4 NPT 1 4 NPT Lamp Out Translucent Translucent Translucent Translucent Translucent Indicator Sight Port Sight Port Sight Port Sight Port Sight Port Ultraviolet Monitor Optional Optional Optio...

Страница 15: ... Time Indicator Universal Input MP13A through MP49C Wall Mounting Kit MP13A through MP49C Time Delay Mechanism MP13A through MP49C Quantum Thermal Optimizer MP13A through MP49C Solenoid Valve Nylon 120v only MP13A 1 2 through MP22A 3 4 c MP36C 1 c MP13A 1 2 through MP22A 3 4 Solenoid Valve Brass MP36C 1 MP49C 1 1 2 c MP49C 1 1 2 MP13A 1 2 MP16A 3 4 Flow Control Valve d MP22A 3 4 MP36C 1 MP49C 1 1 ...

Страница 16: ...16 REPLACEMENT PARTS Mighty Pure Models MP13A MP16A MP22A Figure 6 Exploded View MP13A MP16A MP22A ...

Страница 17: ...A 9 Quartz Sleeve 1 15 1110A 1 15 1111A 1 15 1112A 10 Sight Port Plug 1 30 1075 1 30 1075 1 30 1075 11 Drain Plug 1 27 1216 1 27 1216 1 27 1216 12 Speed Nut 6 32 2 50 1314 13A Ballast 120v 60Hz 1 10 1070 1 10 1327 1 10 1036 13B Ballast 220v 50Hz 1 10 1074 1 10 1327 1 10 1036 14 Screw Mounting 2 50 0155 4 50 0155 4 50 0155 15 Ballast Housing 1 25 1104A 1 25 1105B 1 25 1544D 16 Screw No 8 x 3 8 long...

Страница 18: ...18 REPLACEMENT PARTS Mighty Pure Models MP36C MP49C Figure 7 Exploded View MP36C MP49C ...

Страница 19: ...mber 1 25 1465G4 1 25 1465F5 12 Drain Plug 1 27 1216 1 27 1216 13 Screw 1 4 20 x 3 8 long 4 50 1034 4 50 1034 14 Lock Washer 1 4 4 50 1321 4 50 1321 15 Flat Washer 1 4 4 50 1317 4 50 1317 16 Ballast Housing Cover 1 25 0394A 1 25 0350A 17 Screw No 8 x 3 8 long 8 50 1323 8 50 1323 18 Speed Nut 6 32 2 50 1314 19A Ballast 120v 60Hz 1 10 1036 1 10 1091 19B Ballast 220v 50Hz 1 10 1036 1 10 0127 20 Balla...

Страница 20: ...e use of or inability to use our product for any purpose whatsoever PATENT NOTICE No attempt has been made to determine the patent status of applications illustrated or described in this publi cation Inclusion in this publication of any design or method of use which may be patented is not to be con strued as promoting or sanctioning unauthorized use USER ASSISTANCE Purchased From Date Model Serial...

Отзывы: